Determination of Ultra-trace Migration of Hexavalent Chromium in Toy Materials by Online Enrichment/High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
|更新时间:
|
Determination of Ultra-trace Migration of Hexavalent Chromium in Toy Materials by Online Enrichment/High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
欧阳雨, 曹国樟, 刘崇华, 田勇, 刘欣欣. Determination of Ultra-trace Migration of Hexavalent Chromium in Toy Materials by Online Enrichment/High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry[J]. 2019, 38(12): 1498-1502.
DOI:
欧阳雨, 曹国樟, 刘崇华, 田勇, 刘欣欣. Determination of Ultra-trace Migration of Hexavalent Chromium in Toy Materials by Online Enrichment/High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry[J]. 2019, 38(12): 1498-1502.DOI: doi:10.3969/j.issn.1004-4957.2019.12.015.
Determination of Ultra-trace Migration of Hexavalent Chromium in Toy Materials by Online Enrichment/High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
A method of high performance liquid chromatography-inductively coupled plasma mass spectrometry(HPLC-ICP-MS) with online enrichment was established for the determination of ultra trace migration of hexavalent chromium in toy materials.The hexavalent chromium in the sample was firstly concentrated with an Agilent BIO WAX NP5 anion exchange column(4.6 mm×50 mm
5 μm) using 10 mmol/L ammonium nitrate as mobile phase
then transfered to a Dionex AG7 anion column(4.0 mm×50 mm
10 μm) through a valve switching
separated by elution with 75 mmol/L ammonium nitrate
and finally analyzed by ICP-MS.The on line enrichment time was set at 4 min
the injection volume was 900 μL
the flow rate in enrichment path was 0.4 mL/min
and the off flow rate was 0.6 mL/min.Results showed that there was a good linearity for hexavalent chromium in the range of 2-20 ng/L
with a detection limit of 1.93 ng/L and a relative standard deviation(RSD) of 3.9%.Compared with the conventional sample injection
this method had an about 8.1 times higher enrichment factor with enrichment efficiency of 90%.Samples from three categories of toy materials according to Directive 2009/48/EC of the European Parliament and of the Council of 18 June 2009 on the Safety of Toys were spiked at 5 ng/L and 10 ng/L
and recoveries for hexavalent chromium were in the range of 93.4%-111%.
Determination of Five Bromine Contained Preservatives in Cosmetics by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
Gold Nanoparticle Modified Polymer Monolithic Microextraction Combined with ICP-MS for On-line Analysis of Trace Elements in Cells
Research on the Law of“Quantity-Quality”Transfer of the Standard Decoction of Calcined Ostreae Concha
Determination of Water-soluble Sugars in Tobacco Flavors Based on Ultrasonic Assisted Extraction Coupled with HPLC-ELSD
Comparative Study of Py/GC-MS and TD/GC-MS for Determining Microplastic Mass Abundance in Soils Surrounding Waste Incineration Plants
Related Author
潘晨
王枚博
吴思霖
王欣美
于建
张凯
王柯
郑荣
Related Institution
上海市食品药品检验所
Department of Chemistry,Wuhan University
School of the Fifth Clinical Medicine,Guangzhou University of Chinese Medicine
Guangdong Provincial Engineering Technology Research Institute of Traditional Chinese Medicine
Guangdong Provincial Key Laboratory of Research and Development in Traditional Chinese Medicine