Rapid and Sensitive Determination of Available Phosphorus in Soil by Capillary Electrophoresis with On-line Preconcentration and Contactless Conductivity Detection
Experimental Techniques and Methods|更新时间:2022-06-22
|
Rapid and Sensitive Determination of Available Phosphorus in Soil by Capillary Electrophoresis with On-line Preconcentration and Contactless Conductivity Detection
Journal of Instrumental AnalysisVol. 41, Issue 5, Pages: 787-791(2022)
QI Pei-shan,ZHU Pen-sheng,XIE Tian-yao.Rapid and Sensitive Determination of Available Phosphorus in Soil by Capillary Electrophoresis with On-line Preconcentration and Contactless Conductivity Detection[J].Journal of Instrumental Analysis,2022,41(05):787-791.
QI Pei-shan,ZHU Pen-sheng,XIE Tian-yao.Rapid and Sensitive Determination of Available Phosphorus in Soil by Capillary Electrophoresis with On-line Preconcentration and Contactless Conductivity Detection[J].Journal of Instrumental Analysis,2022,41(05):787-791. DOI: 10.19969/j.fxcsxb.21102801.
Rapid and Sensitive Determination of Available Phosphorus in Soil by Capillary Electrophoresis with On-line Preconcentration and Contactless Conductivity Detection
A new method for the rapid separation and sensitive determination of available phosphorus in soil by capillary electrophoresis(CE) with field-amplified sample injection(FASI) and capactively coupled contactless conductivity detection(C,4,D) was developed.Parameters affecting the CE separation and FASI efficiency were investigated in detail,including the composition and pH value of running buffer solution,separation voltage,sample injection voltage and time.The analyte was well separated and sensitively detected within 8 min in a fused-silica capillary under the optimum conditions of 35 mmol/L acetic acid - 2 mmol/L ammonium acetate as running buffer,with separation voltage of -14 kV,electrokinetic injection of -11 kV × 10 s.The calibration curve showed good linearity in the range of 16-800 μg/L,with a limit of detection of 5 μg/L.As a result,FASI showed significant increase of sensitivity with an enhancement factor of 580.The intra- and inter-relative standard deviations(RSD) were below 5.0%.The co-existed inorganic anion(Cl,-,,SO,,http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=37248257&type=,http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=37248254&type=,2.53999996,3.72533321,,NO,,http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=37248263&type=,http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=37248260&type=,1.10066664,3.72533321,) and organic acid did not interfere with the detection of available phosphorus in soil.Contents of available phosphorus in soil samples could be easily determined without complex sample pretreatment.This proposed method could meet the requirements for the fast screening and sensitive detection of available phosphorus in soil samples.
Determination of Polyoxin B in Soils by Capillary Electrophoresis with Electrochemiluminescence Detection
Determination of Ibuprofen Arginine by Contactless Conductivity Detection with Microfluidic Chip
Simultaneous Determination of 12 Organophosphate Esters in Soil by Solid Phase Extraction/High Performance Liquid Chromatography-Tandem Mass Spectrometry
Simultaneous Detection of Pesticides and Antibiotics Residues in Soil by QuEChERS/Ultra Performance Liquid Chromatography- Tandem Mass Spectrometry
Determination of Fluoroquinolones in Environmental Water Samples by Capillary Electrophoresis with Dispersive Liquid-Liquid Microextraction Based on Ultrasonic-assisted in-situ Formation and Solidification of Floating Deep Eutectic Solvent
Related Author
No data
Related Institution
西北师范大学化学化工学院甘肃省高分子材料重点实验室省部共建生态环境相关高分子材料教育部重点实验室
中山大学药学院
College of Carbon Neutral Modern Industry,College of Environmental and Resource Science,Fujian Normal University
Fujian Key Laboratory of Pollution Control and Resource Reuse
Fujian College Association Instrument Analysis Center,Fuzhou University