1.江南大学 机械工程学院 包装工程系,江苏 无锡 214122
2.江苏省食品先进制造装备 技术重点实验室,江苏 无锡 214122
卢立新,博士,研究方向:食品包装技术与安全、包装系统与装备研究,E - mail:lulx@jiangnan.edu.cn
扫 描 看 全 文
程畅,卢立新,潘嘹等.液相色谱-串联质谱法测定食品接触橡胶密封垫圈中7种抗氧化剂[J].分析测试学报,2021,40(07):1074-1079.
CHENG Chang,LU Li-xin,PAN Liao,et al.Determination of 7 Antioxidants in Rubber Seal Gaskets for Food Contact by Liquid Chromatography-Tandem Mass Spectrometry[J].Journal of Instrumental Analysis,2021,40(07):1074-1079.
程畅,卢立新,潘嘹等.液相色谱-串联质谱法测定食品接触橡胶密封垫圈中7种抗氧化剂[J].分析测试学报,2021,40(07):1074-1079. DOI: 10.3969/j.issn.1004-4957.2021.07.015.
CHENG Chang,LU Li-xin,PAN Liao,et al.Determination of 7 Antioxidants in Rubber Seal Gaskets for Food Contact by Liquid Chromatography-Tandem Mass Spectrometry[J].Journal of Instrumental Analysis,2021,40(07):1074-1079. DOI: 10.3969/j.issn.1004-4957.2021.07.015.
采用液相色谱-串联质谱技术建立了食品接触橡胶密封垫圈中7种抗氧化剂(抗氧化剂ZKF、抗氧化剂259、抗氧化剂1035、抗氧化剂425、抗氧化剂2246、抗氧化剂1520、抗氧化剂565)的同时检测方法。样品经甲醇微波提取,Acquity UPLC BEH C,18,(100 mm × 2.1 mm,1.7 μm)色谱柱分离,以乙腈-乙酸铵水溶液(5 mmol/L)为流动相进行梯度洗脱,在正、负离子模式下测定。结果显示,7种抗氧化剂在0.01~0.5 mg/L质量浓度范围内线性良好,相关系数(,r,2,)均大于0.999。方法检出限(MLOD)为0.005~0.125 mg/kg,方法定量下限(MLOQ)为0.02~0.40 mg/kg,平均加标回收率为73.1%~120%,相对标准偏差(RSD,,n, = 6)为0.70%~9.3%。该方法前处理简单,15 min内可同时完成7种抗氧化剂的检测,且检出限较低,可满足食品接触橡胶材料及制品中抗氧化剂的检测需要。
A method was developed for the determination of residues of 7 antioxidants, i.e. antioxidant ZKF, antioxidant 259, antioxidant 1035, antioxidant 425, antioxidant 2246, antioxidant 1520 and antioxidant 565 in rubber seal gaskets for food contact by liquid chromatography-tandem mass spectrometry. By optimizing the chromatographic column, elution procedure and mass spectrometry conditions, the optimal detection conditions were determined. The rubber powder sample was obtained by freezing and grinding the rubber sample with a freezing grinding instrument. After comparing the recoveries of three kinds of filter membranes and high-speed centrifugation, the high-speed centrifugation method was adopted to pretreat the extract. In addition, three extraction methods including ultrasonic, reflux and microwave, and two extraction solvents including methanol and acetone were used to extract the antioxidants from the positive rubber powder samples to obtain the extraction solution. Microwave extraction with methanol was determined as the optimal pretreatment method with the extraction recovery and extraction efficiency as the evaluation indexes. The rubber powder samples(g) and methanol(mL) were mixed by the ratio of 1∶20, then extracted at 50 ℃ for 15 minutes under microwave condition. After high-speed centrifugation treatment, the extracted liquid samples were detected by liquid chromatography-tandem mass spectrometry. The separation was performed on an Acquity UPLC BEH C,18,(100 mm × 2.1 mm, 1.7 μm) column by gradient elution with acetonitrile-ammonium acetate aqueous solution(5 mmol/L) as the mobile phase, and the determination was carried out in positive and negative ion modes. Results showed that the limits of detection(LOD), limits of quantitation(LOQ), method limits of detection(MLOD) and method limits of quantitation(MLOQ) for the 7 antioxidants were in the ranges of 0.003-0.083 μg/L, 0.01-0.25 μg/L, 0.005-0.125 mg/kg and 0.02-0.40 mg/kg, respectively. There were good linear relationships for the 7 antioxidants in the mass concentration range of 0.01-0.5 mg/L, with their correlation coefficients(,r,2,) all greater than 0.999. The average recoveries ranged from 73.1% to 120% with relative standard deviations(RSD, ,n,=6) of 0.70%-9.3%, which indicated that the developed method was stable and accurate. Finally, 8 kinds of commercial food contact rubber gasket samples were detected by this method. It was found that antioxidant 259, antioxidant 425, antioxidant 1520 and antioxidant 2246 were detected in the commercial samples, while the others were undetected. This method could be used to detect 7 kinds of antioxidants simultaneously within 15 min, with a fast detection speed and a low detection limit, which could meet the needs for detection of antioxidants in food contact rubber materials and products.
液相色谱-串联质谱食品接触橡胶密封垫圈抗氧化剂微波萃取
liquid chromatography-tandem mass spectrometryrubber seal gasket for food contactantioxidantmicrowave extraction
Wang G, Wang J, Wang L J, Xin M R. Synth. Mater. Aging Appl.(王刚,王鉴,王立娟,辛明睿. 合成材料老化与应用),2006, 35(2): 38-42.
Chang Y, Kang K, Park S J, Choi J C, Kim M K, Han J. J. Food Eng., 2018, 244: 142-149.
GB 9685-2016. Standard for Use of Additives for Food Contact Materials and Products. National Standards of the People's Republic of China(食品接触材料及制品用添加剂使用标准.中华人民共和国国家标准).
Chen L W, Wu C S, Wang Y, Wu Y L, Wang L, Dong H, Wang B, Luo H Y. J. Instrum. Anal.(陈立伟,吴楚森,汪毅,吴玉銮,王莉,董浩,王斌,罗海英.分析测试学报), 2016, 35(2): 206-212.
Galotto M J ,Torres A,Guard A,Moraga N, Romero J. Food Res. Int., 2011, 44(2): 566-574.
Wang H Y, Zhang Y F, Ying J Y. China Rubber Sci. Technol. Mark.(王华英, 张隐峰, 应俊扬.橡胶科技), 2013, 11(3): 42-46.
Jiang X H. Chem. Anal. Meterage(姜晓辉.化学分析计量), 2009, 18(3): 65-66.
Lutzhoft H H, Waul C K, Andersen H R, Seredynskasobecka B, Mosbaek H, Christensen N, Arvin E. Int. J. Environ.Anal. Chem., 2013, 93(6): 593-612.
Wang J C, Li S F, Xiong X T, She W X, Chen Y G, Liu D Y, Tan J H, Li H Y, Xi S F. J. Instrum. Anal.(王继才,李少飞,熊小婷,佘文勋,陈意光,刘德云,谭建华,李慧勇,席绍峰.分析测试学报), 2018, 37(7): 815-819.
Liang X Z, Sui H X, Li D, Zhong H N. J. Instrum. Anal.(梁锡镇,隋海霞,李丹,钟怀宁.分析测试学报), 2018, 37(1): 87-91.
Garridolopez A, Tena M T. J. Chromatogr. A, 2005, 1099(1): 75-83.
Molander P, Haugland K, Hegna D R, Ommundsen E, Lundanes E, Greibrokk T. J. Chromatogr. A, 1999, 864(1):103-109.
Liu J L. Chem. Enterp. Manag.(刘洁兰.化工管理), 2013, (12): 64-64, 66.
Li X M, Song H, Lin Q B, Wang T J. Chem. Res. Appl.(李小梅,宋欢,林勤保,王天骄.化学研究与应用), 2010, 22(8): 980-984.
Marcato B, Vianello M. J. Chromatogr. A, 2000, 869(1): 285-300.
Li H F, Li Z H, Wang L B, Li J L, Zhang H. Food & Machinery(李浩峰,李忠海,王利兵,黎继烈,张慧.食品与机械),2013, 29(1): 88-91.
Arias M, Penichet I, Ysambertt F, Bauza R, Zougagh M, Rios A. J. Supercrit. Fluids, 2009, 50(1): 22-28.
Xiong Z Q, Wang L B, Li N T, Yu Y J, Jia X C. Chin. J. Chromatogr.(熊中强,王利兵,李宁涛,于艳军,贾晓川.色谱), 2011, 29(3): 273-276.
Zhou X J, Zhao Y Q, Li W, Xie J J. Sci. Technol. Food Ind.(周相娟,赵玉琪,李伟,谢精精. 食品工业科技), 2010, (9): 288-289, 297.
Hu G H, Shi Y J, Qian C, Li Q M, Gao X, Liu W L. Anal. Instrum.胡光辉,史迎杰,钱冲,李琴梅,高峡,刘伟丽.分析仪器), 2018, (5): 115-119.
Li Z W, Wang H, Lin L F, Zhang L L, Yan H L. Chem. Anal. Meterage(李支薇,王华,林炼锋,张兰兰,严洪连.化学分析计量), 2018, 27(3): 73-76.
Li W, Liu Y C, Duan J M. Chin. J. Anal. Chem.李伟,刘玉灿,段晋明. 分析化学), 2015, (11): 1761-1765.
0
浏览量
5
下载量
2
CSCD
关联资源
相关文章
相关作者
相关机构