1. 闽江学院化学与化学工程系
2. 福州大学食品安全与检测教育部重点实验室
扫 描 看 全 文
李艳霞, 陈国南. 基于HRP直接标记的流感病毒H1N1电化学免疫传感器[J]. 分析测试学报, 2015,34(6):701-705.
A Novel Electrochemical Immunosensor for Influenza A(H1N1) Virus Recognition Based on HRP Direct Labelling[J]. 2015,34(6):701-705.
构建了一种新型、灵敏、便捷式流感病毒免疫传感器,通过在金电极表面键合抗-HA单克隆抗体,选择性捕获目标H1N1流感病毒。该方法基于吸附在病毒表面的辣根过氧化物酶(HRP)在亚甲基蓝(MB)溶液中可有效催化还原H2O2,利用方波伏安法(SWV)考察了还原峰电流的变化,从而实现了对抗原病毒的特异性识别。实验表明所构建的免疫传感器对H2O2-MB体系表现出快速的电流响应以及良好的稳定性,对流感病毒H1N1检测的动态响应范围为0.01~2.0 μg/mL,检出限(S/N= 3)为5.0 ng/mL。结果证明HRP可作为一种简单快速的探针用于流感病毒的实时监测。
An immunosensor for the sensitive and simple recognition of low concentrations of influenza viruses was constructed.Gold electrode was coated with H1 subtype-specific monoclonal antibodies to selectively capture the target virus.Horseradish peroxidase(HRP) as a catalyst to reduce hydrogen peroxide(H2O2) in the methylene blue(MB) solution was immobilized on the biosensor.The change of reduction peak current for specific recognition of antigen virus was monitored by square wave voltammetry(SWV).The biosensor exhibited a fast amperometric response and a good stability to H2O2-MB system.The dynamic range for antigen recognition was in the range of 0.01-2.0 μg/mL with a detection limit(S/N=3) of 5.0 ng/mL.The results indicated that HRP had a good sensitivity and a simple operation for the detection of influenza virus.
电化学免疫分析甲型流感病毒H1N1辣根过氧化物酶
electrochemical immunoassayinfluenza A(H1N1) virusHRP
0
浏览量
1125
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构