Determination of Residues of 21 Harmful Organic Solvents in Leather and Leather Products by Gas Chromatography-Mass Spectrometry Combined with Ultrasonic Extraction
Determination of Residues of 21 Harmful Organic Solvents in Leather and Leather Products by Gas Chromatography-Mass Spectrometry Combined with Ultrasonic Extraction[J]. 2016,35(4):380-387.
Determination of Residues of 21 Harmful Organic Solvents in Leather and Leather Products by Gas Chromatography-Mass Spectrometry Combined with Ultrasonic Extraction[J]. 2016,35(4):380-387.DOI:
A method was established to determine simultaneously the residues of 21 harmful organic solvents in leather and leather products by gas chromatography-mass spectrometry in selected ion monitoring mode(GC-MS/SIM).Residual harmful organic solvents in leather and leather products were ultrasonically extracted at 45℃,using ethyl acetate as extraction solvent.The extracts were purified with solid-phase extraction(SPE) columns,and then analyzed by gas chromatography-mass spectrometry in selected ion monitoring mode(GC-MS/SIM).The content of each analyte was calibrated by the external standard method.At the condition of signal to niose(S/N) of ten,the limits of quantitation(LOQs) were 50μg/kg for ethylene glycol dibutyl ether(EGDBE),triethylene glycol dimethyl ether(TEGDME),diethylene glycol butyl ether(DEGBE) and triethylene glycol ethyl ether(TEGEE),150μg/kg for N-methylformamide(MF) and N-methylacetamide(MA),300μg/kg for formamide,and 100μg/kg for all the other fourteen compounds.The spiked average recoveries varied from 82.1% to 94.9% at three spiked levels with relative standard deviations(RSD) of 1.6%-4.8%.The proposed method was simple,rapid,accurate and sensitive,and was suitable for the determination of residual harmful organic solvents in leather and leather products.
关键词
超声萃取气相色谱-质谱选择离子监测皮革乙二醇醚酰胺N-甲基吡咯烷酮
Keywords
ultrasonic extractiongas chromatography-mass spectrometry(GC-MS)selected ion monitoring(SIM)leatherglycol ethersamidesN-methylpyrrolidone