An analytical method was developed for the determination of 8 pyrethroid pesticide residues in nuts(hawaii nuts,pigeon nuts,almonds imported from ASEAN).The samples were extracted with acetonitrile by ultrasonic technique,purified with Alumina-N SPE and Florisil SPE.The components were separated with two different polarity capillary columns,and 8 kinds of pyrethroid pesticide residues were detected by GC with ECD detector.The linear range of the method was in the range of 0.01-1.0 μg/mL(r=0.999 2-0.999 9).The recoveries at three spiked concentrations of 10,20,50 μg/kg were in the range of 71%-115%,with relative standard deviations(RSD) of 4.5%-9.8%.The limits of detection(LOD,S/N=3) were in the range of 0.014-0.28 μg/kg.The limits of quantitation(LOQ,S/N=10) were in the range of 0.047-0.94 μg/kg.The established method has the advantages of good separation,high accurancy,high recovery, convenience and rapidness,and could be used for the routine analysis of pesticide residues in nuts.
关键词
气相色谱法(GC)拟除虫菊酯类农药夏威夷果开心果杏仁
Keywords
gas chromatography(GC)pyrethroid pesticideHawaii nutspigeon nutsalmonds