黄颖, 张翠云. 免标型沙丁胺醇免疫电化学传感器[J]. 分析测试学报, 2018,37(2):247-251.
A Label-free Electrochemical Salbutamol Immunosensor[J]. 2018,37(2):247-251.
构建了以茜素为探针,二氧化钛掺杂乙炔黑和壳聚糖复合材料为信号放大平台的新型免标型沙丁胺醇免疫传感器。于修饰电极的表面电沉积金纳米粒子,实现沙丁胺醇抗体的固定并进一步增大电流响应。采用扫描电子显微镜(SEM)对材料进行表征,循环伏安法(CV)和电化学阻抗谱图(EIS)对修饰电极的构建过程及传感器的性能进行电化学表征。采用差分脉冲伏安法(DPV)检测茜素在修饰电极表面的峰电流值,不同浓度的沙丁胺醇(SAL)抗原与抗体发生免疫亲和反应后,该峰电流值随着沙丁胺醇浓度的增大而减小,并呈线性关系,据此建立峰电流值与沙丁胺醇浓度的关系并实现了对沙丁胺醇的定量检测。探究了缓冲溶液pH值、孵化温度和孵化时间对免疫传感器的影响。在最佳条件下,该免疫传感器对沙丁胺醇的线性响应范围为1.0~100 μg/L,检出限(LOD)为0.67 μg/L(3σ/k)。该免疫传感器具有良好的重现性、选择性和稳定性,已成功用于猪饲料和猪肉样品中沙丁胺醇的检测,加标回收率分别为100.2%~102.4%(相对标准偏差为1.9%~4.7%)和97.5%~103.3%(相对标准偏差为2.1%~3.5%)。
A novel and label free electrochemical immunosensor for salbutamol(SAL) detection was developed with alizarin (AR) as a redox probe,and titanium dioxide hybridized acetylene black and chitosan composites (TiO2-AB-CS) as a signal amplification platform.Au NPs were electro deposited on the modified electrode surface to immobilize the SAL antibody(anti SAL),which could further enhance the current response.Scanning electron microscope(SEM) was used to characterize the materials.Cyclic voltammetry(CV) and electrochemical impedance spectroscopy(EIS) were used to characterize the construction process of modified electrode and the electrochemical properties of the immunosensor.Differential pulse voltammetry(DPV) was used to detect the peak current of alizarin on the surface of modified electrode,the peak current of the proposed immunosensor decreased linearly with the increase of SAL concentration when the immune-reaction was carried out with anti-SAL,and the relationship between the peak current and SAL concentration was established to accomplish the quantitative detection on SAL.The experimental factors affecting current response were explored,including pH of phosphate buffer solution (PBS),incubation temperature and incubation time.Under the optimized conditions,the linear range of the immunosensor was obtained to be 1.0-100 μg/L with a limit of detection(LOD) of 0.67 μg/L(3σ/k).With the advantages of good reproducibility,specificity and stability,the immunosensor was successfully applied in the detection of SAL in swine feed and pork samples with satisfactory results.The recoveries of SAL in swine feed and pork were in the ranges of 100.2%-102.4% and 97.5%-103.3% with relative standard deviations(RSDs) of 1.9%-4.7% and 2.1%-3.5%,respectively.
乙炔黑茜素金纳米粒子沙丁胺醇二氧化钛
acetylene blackalizarinAu NPssalbutamoltitanium dioxide
0
浏览量
513
下载量
4
CSCD
关联资源
相关文章
相关作者
相关机构