王兴龙, 蔡强, 桂文锋, 蔡增轩, 许娇娇, 任一平. Analysis of Ochratoxin A in Wine by Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry with Stable Isotope Direct Dilution[J]. 2019, 38(11): 1379-1383.
DOI:
王兴龙, 蔡强, 桂文锋, 蔡增轩, 许娇娇, 任一平. Analysis of Ochratoxin A in Wine by Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry with Stable Isotope Direct Dilution[J]. 2019, 38(11): 1379-1383.DOI: doi:10.3969/j.issn.1004-4957.2019.11.016.
Analysis of Ochratoxin A in Wine by Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry with Stable Isotope Direct Dilution
An ultra high performance liquid chromatography-tandem mass spectrometric(UPLC-MS/MS) method was established for the determination of ochratoxin A(OTA) in wine based on stable isotope direct dilution technique.Samples were diluted with acetonitrile-water-formic acid(298∶70∶0.2
by volume)
and the matrix effects were efficiently compensated with the 13C20-labelled internal standard.The analyte was separated on an ACQUITY BEH C18 column(100 mm×2.1 mm
1.7 μm) by gradient elution with 0.1% formic acid solution and 0.1% formic acid acetonitrile as mobile phases
and then analyzed under multiple reaction monitoring(MRM) mode in ESI+ mode.Results showed that there was a good linearity for OTA in the range of 0.05-1 μg/L with a correlation coefficient(r2) of 0.999 6.The limit of detection(LOD
S/N≥3) and the limit of quantitation(LOQ
S/N≥10) of the method were 0.1 μg/L and 0.3 μg/L
respectively.Recoveries at three spiked levels of 1.00
2.00
5.00 μg/L ranged from 102% to 113%
with intra day RSDs and inter day RSDs of 4.1%-9.4% and 4.4%-9.7%
respectively.The method was applied in the analysis of OTA in fifteen red wines and five white wines made in China
and OTA was undetected in all wines.The method was simple
effective and low-consumption
and was suitable for the determination of OTA in wine.
Study on Rapid Determination of More than 40 Mineral Elements in Human Serum by Inductively Coupled Plasma Mass Spectrometry
Origin Traceability of Wine Based on Untargeted Metabolomics
Development and Evaluation of a Light-emitting Diode Induced Fluorescence Detector Based on Light Source Switching
Analysis of Microplastic Release Behavior During Aging-Degradation of PBAT Based on Multi-technology Combined Detection
Analysis of Adsorption Interaction Mechanism between Polyvinyl Chloride Microplastics and Phenanthrene Derivatives Based on Two-dimensional Correlation Spectroscopy
Related Author
YAO Xue-man
XIA Yu
ZHANG Qiu-ping
JIANG Jian-rong
WANG Xin
LIU Xu-yan
LI Mi
GONG Zhi-guo
Related Institution
School of Public Health,Nanjing Medical University
Jiangsu Key Laboratory of Food Safety Risk Monitoring(Illegal Addition Field)