Determination of Aflatoxins in Aquatic Feeds Samples by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Multi component Immunoaffinity Column Purification
|更新时间:
|
Determination of Aflatoxins in Aquatic Feeds Samples by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Multi component Immunoaffinity Column Purification
刘文静, 余海霞, 严忠雍, 张小军, 丁国芳. Determination of Aflatoxins in Aquatic Feeds Samples by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Multi component Immunoaffinity Column Purification[J]. 2019, 38(3): 323-327.
DOI:
刘文静, 余海霞, 严忠雍, 张小军, 丁国芳. Determination of Aflatoxins in Aquatic Feeds Samples by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Multi component Immunoaffinity Column Purification[J]. 2019, 38(3): 323-327.DOI: doi:10.3969/j.issn.1004-4957.2019.03.011.
Determination of Aflatoxins in Aquatic Feeds Samples by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Multi component Immunoaffinity Column Purification
An ultra performance liquid chromatography-tandem mass spectrometric(UPLC-MS/MS) method was established for the determination of aflatoxins(AFB1
AFB2
AFG1 and AFG2)in aquatic feeds based on multi-component immunoaffinity column purification.The samples were ultrasonically extracted with 80%acetonitrile aqueous solution
then purified with a multi-component immunoaffinity column
finally analyzed by UPLC-MS/MS with electrospray ionization in positive ion mode(ESI+)under multiple reaction monitoring(MRM)mode and quantified by the external standard method.The separation was performed on an Acquity UPLC BEH C18 column by gradient elution with 0.1%formic acid-acetonitrile as mobile phases.Good linear responses were obtained in the concentration ranges of 2.25-22.5 ng/mL for AFB1 and AFG1
and 0.75-7.5 ng/mL for AFB2 and AFG2
with their correlation coefficients larger than 0.997
respectively.The limits of quantitation(LOQs) were 0.7 μg/kg for AFB1 and AFG1
and 0.2 μg/kg for AFB2 and AFG2
respectively.The average recoveries for AFB1 and AFG1 at a spiked level of 1.5 μg/kg
and AFB2 and AFG2 at a spiked level of 0.5 μg/kg ranged from 78.7%to 85.5%
with intra-day and inter-day relative standard deviations of 6.0%-6.5%and 6.6%-7.0%
respectively.The method was simple
rapid
sensitive and reliable
and was suitable for the determination of aflatoxins residues in aquatic feed samples.
Determination of 11 Doping Agents in Soft Capsule-type Chinese Patent Medicines by QuEChERS/Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of 17 Bisphenols in Silicone Wristbands by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Quinolinecarboxylic Acid-linked Covalent Organic Framework Microsphere for On-line Solid Phase Extraction of Four Aflatoxins
Analysis of Adsorption Interaction Mechanism between Polyvinyl Chloride Microplastics and Phenanthrene Derivatives Based on Two-dimensional Correlation Spectroscopy
A Novel Toxicity Analysis Method for Oxidative Damage Based on Normalized Physical Characteristic Exposure to Microplastics
Related Author
ZHANG Wei
LI Chun-yu
FEI Qiao-ling
ZHAO Xue-jun
REN Jia-le
LIU Yue-han
SUN Jia-lin
NIU Yu-min
Related Institution
Shanghai Key Laboratory of On-site Physical Evidence
Food and Drug Testing Laboratory of Anti Doping Center of General Administration of Sport of China
School of Investigation,People's Public Security University of China
Chaoyang District Center for Disease Prevention and Control,Beijing
School of Public Health,Capital Medical University,Beijing