QIU Tian,BAO Shan,JIANG Wei-long,et al.Determination of 43 Persistent Organochlorine Pollutants in Human Serum by Gas Chromatography-Tandem Mass Spectrometry[J].Journal of Instrumental Analysis,2023,42(07):775-783.
QIU Tian,BAO Shan,JIANG Wei-long,et al.Determination of 43 Persistent Organochlorine Pollutants in Human Serum by Gas Chromatography-Tandem Mass Spectrometry[J].Journal of Instrumental Analysis,2023,42(07):775-783. DOI: 10.19969/j.fxcsxb.23031003.
Determination of 43 Persistent Organochlorine Pollutants in Human Serum by Gas Chromatography-Tandem Mass Spectrometry
A gas chromatography-tandem mass spectrometric(GC-MS/MS) method was developed for the simultaneous analysis of 43 persistent organochlorine pollutants(POCPs),including 18 polychlorinated biphenyls(PCBs) and 25 organochlorine pesticides(OCPs) in human serum,based on solvent extraction coupled with solid-phase extraction cartridge cleanup.Human serum samples were thawed and brought to room temperature before pretreatment.An aliquot of 250 µL serum sample was transferred into a 12 mL glass tube.Protein was precipitated using methanol and lipid was removed by acidification to release target analytes.A liquid-liquid extraction was performed using hexane and methyl ,tert,-butyl ether in turn.The extract from both solvent was combined and concentrated.The sample was further purified using silica gel solid-phase extraction cartridges,then concentrated to near-dryness under gentle stream of nitrogen and reconstituted with toluene.Subsequently,the chromatographic separation was performed on a TG-5SilMS(30 m × 0.25 mm × 0.25 µm) column.The target analytes were monitored under multiple reaction monitoring(MRM) mode,and quantified by internal standard method.The results showed that there were good linear relations for the 18 PCBs and 25 OCPs in the ranges of 0.008-1 µg/L and 0.08-10 µg/L,with the detection limits and the quantitation limits of 0.005-0.1 µg/L and 0.02-0.3 µg/L,respectively.The matrix effect was in the range of 74.9%-126%.The spiked recoveries ranged from 71.6% to 129%,with intra-day relative standard deviations(RSDs) and inter-day RSDs of 1.0%-11% and 1.3%-18%,respectively.To evaluate method accuracy,standard reference material purchased from the US National Institute of Standards and Technology was used.The relative deviations of tested results were lower than 30% compared to certified values.The developed method was applied to the determination of 173 serum samples collected from general population.A total of 28 POCPs were detected,of which ,p,,,p,′-DDE and PCB 153 both had a detection frequency over 50%,and the median concentration of ,p,,,p,′-DDE was found to be 0.46 µg/L,making it the primary POCPs in the serum samples of this particular population.This analytical method is suitable for the detection on 43 POCPs in human serum samples as it could effectively control the matrix effect and improve the analytical sensitivity.
关键词
气相色谱-串联质谱持久性有机氯污染物液液萃取固相萃取人血清
Keywords
gas chromatography-tandem mass spectrometrypersistent organochlorine pollutantsliquid-liquid extractionsolid-phase extractionhuman serum
references
Han X,Meng L L,Li Y M,Li A,Turyk M E,Yang R Q,Wang P,Xiao K,Zhao J P,Zhang J Q,Zhang Q H,Jiang G B.Chemosphere,2020,241:125030.
Zheng M H,Tan L,Gao L R,Ma L J,Dong S J,Yao Y W.Environ. Monit. China(郑明辉,谭丽,高丽荣,马莉娟,董姝君,姚雅伟.中国环境监测),2019,35(1):1-7.
Yu L,Zhao Z S,Zhao J,Xiang Z M.J. Instrum. Anal. (余磊,赵志燊,赵杰,向章敏.分析测试学报),2021,40(8):1184-1189.
Schisterman E F,Whitcomb B W,Louis G M,Louis T A.Environ. Health Perspect.,2005,113(7):853-857.
Nøst T H,Breivik K,Fuskevåg O M,Nieboer E,Odland J Ø,Sandanger T M.Environ. Health Perspect.,2013,121(11/12):1292-1298.
Zhao P,Shi J W,Li J G,Xu F F,Gong W J,Qiu L X.Chin. J. Anal. Chem. (赵鹏,施家威,李继革,徐奋奋,龚文杰,裘立晓.分析化学),2015,43(5):651-657.
Palát J,Kukučka P,Codling G P,Price E J,Janků P,Klánová J.Chemosphere,2022,287(3):132300.
Johnson C L,Jazan E,Kong S W,Pennell K D.Environ. Sci. Pollut. Res.,2021,28(3):3266-3279.
Fang J,Wu Q,Zhao Y,Zhao H Z,Xu S Q,Cai Z W.J. Chromatogr. B,2017,1040:180-185.
Pérez J J,Williams M K,Weerasekera G,Smith K,Whyatt R M,Needham L L,Barr D B.J. Chromatogr. B,2010,878(27):2554-2562.
Zhang L F,Zhang L L,Li X X,Dong L,Huang Y R.Environ. Chem. (张利飞,张琳利,李晓秀,董亮,黄业茹.环境化学),2014,33(8):1261-1268.
World Health Organization European Centre for Environment and Health. Health Risks of Persistent Organic Pollutants from Long-range Transboundary Air Pollution,2022.[2023-03-10]. https://www.who.int/europe/publications/i/item/EUR-03-5042687https://www.who.int/europe/publications/i/item/EUR-03-5042687.
Li X,Wang L M,Song L L,Wan Z C,Kou J,Zhang M Y,Lü Y M,Wang Y J,Mei S R.Chin. J. Chromatogr. (李想,王丽梅,宋璐璐,万政策,寇婧,张明烨,吕永曼,王友洁,梅素容.色谱),2022,40(5):461-468.
Kong D M,Chen C,Zhou Q D,Liu Z H,Guo P R.J. Instrum. Anal. (孔德明,陈超,周启动,刘则华,郭鹏然.分析测试学报),2023,42(2):216-220.
Wang M M,Xie L N,Zhu Y,Lu Y F.Chin. J. Chromatogr. (王梦梦,谢琳娜,朱英,陆一夫.色谱),2022,40(4):354-363.
Zhang J X,Zheng X Y,Tan L,Liu J B,Yu H B.Chin. J. Chromatogr. (张静星,郑晓燕,谭丽,刘进斌,于海斌.色谱),2021,39(5):541-551.
Liu Q.China Food Saf. (刘琦.食品安全导刊),2019,(26):79-80.
Food and Drug Administration. Bioanalytical Method Validation,2018.[2023-03-15]. https://www.fda.gov/media/70858/downloadhttps://www.fda.gov/media/70858/download.
Li H Y,Liu Y,Li C Y,Wang J.J. Instrum. Anal. (李红艳,刘英,李长于,王瑾.分析测试学报),2023,42(1):1-10.
Xu Y Y,Li S,Zhang Q,Shi L L,Wang J K,Song N H.Agrochemicals(徐炎炎,李森,张芹,石利利,王济奎,宋宁慧.农药),2017,56(3):162-167.
Belarbi S,Vivier M,Zaghouani W,Sloovere A D,Agasse-Peulon V,Cardinael P.Food Chem.,2021,359:129932.
Determination of 10 Alkaloids in Refill Solutions for Electronic Cigarettes by Gas Chromatography-Tandem Mass Spectrometry
Determination of Ethoxyquinoline and Ethoxyquinoline Dimer in Aquatic Products by High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of 16 Phthalate Plasticizers in the Extracts of Plastic Components Used in the Production of Fludeoxyglucose [18F] Injection by Liquid-Liquid Extraction/Gas Chromatography-Mass Spectrometry
Determination of Trace Chlorine Pollutants in Oil-bearing Metal Raw Materials by Gas Chromatography-Tandem Mass Spectrometry with Solid Phase Extraction-Response Surface Optimized Carbon Skeleton Online Catalysis
Determination of Fipronil and Its Metabolites in Rice Fishing Water Samples by SPE/UPLC-MS/MS
Related Author
No data
Related Institution
China Tobacco Guangxi Industrial Co., Ltd.
China National Tobacco Quality Supervision and Test Center
College of Food and Pharmaceutical Engineering,Nanjing Normal University
Animal,Plant and Food Inspection Center,Nanjing Customs
Drug Testing and Packaging Materials Research Center,Jiangsu Pharmaceutical Research Institute;Co.,Ltd.