安娅丽, 赵艳萍, 刘宁, 班睿. Simultaneous Determination of p-Arsanilic Acid,Roxarsone and Their Degradation Products in Soils by HPLC-ICP-MS/MS[J]. 2019, 38(11): 1353-1357.
安娅丽, 赵艳萍, 刘宁, 班睿. Simultaneous Determination of p-Arsanilic Acid,Roxarsone and Their Degradation Products in Soils by HPLC-ICP-MS/MS[J]. 2019, 38(11): 1353-1357.DOI: doi:10.3969/j.issn.1004-4957.2019.11.011.
A high performance liquid chromatography-inductively coupled plasma-tandem mass spectrometry(HPLC-ICP-MS/MS) was developed for the simultaneous determination of six arsenic species
i.ep-arsanilic acid(p-ASA)
roxarsone(ROX) and their degradation products arsenite(As(Ⅲ)) and arsenate(As(Ⅴ))(inorganic arsenic)
monomethylated arsenic(MMA) and dimethylated arsenic(DMA) in soils.The soil samples were extracted with 0.1 mol/L NaH2PO4-01 mol/L H3PO4(9∶1
by volume) as extraction solvent at a liquid to solid ratio of 50 mL/g
by microwave assisted extraction at 80 ℃ for 30 min.Five arsenic species in the extracts were well separated within 15 min on a Hamilton PRP-X100 anion exchange column(250 mm×4.1 mm,10 μm) using 60 mmol/L(NH4)2HPO4 containing 5% methanol(pH 6.0) and water as mobile phases by gradient elution.Under the optimized conditions
there were good linear relationships for the analytes in the concentration range of 0-500 μg/L with their correlation coefficients(r2) not less than 0.999 1.The limits of detection were 0.043-0080 μg/kg for the analytes,and the relative standard deviations ranged from 1.7% to 3.8%.The method was applied in the analysis of three soil samples
and recoveries for the analytes were in the ranges of 71.6%-106%.The developed method is simple
rapid
accurate and reliable
and is suitable for the determination of arsenic species in soils.