Determination of Tetracyclines in Environmental Water Samples by High Performance Liquid Chromatography with Multi template Molecularly Imprinted Polymer Magnetic Solid Phase Extraction
|更新时间:2023-04-18
|
Determination of Tetracyclines in Environmental Water Samples by High Performance Liquid Chromatography with Multi template Molecularly Imprinted Polymer Magnetic Solid Phase Extraction
曾国龙, 马晓国, 樊银明. Determination of Tetracyclines in Environmental Water Samples by High Performance Liquid Chromatography with Multi template Molecularly Imprinted Polymer Magnetic Solid Phase Extraction[J]. 2020, 39(6): 749-755.
DOI:
曾国龙, 马晓国, 樊银明. Determination of Tetracyclines in Environmental Water Samples by High Performance Liquid Chromatography with Multi template Molecularly Imprinted Polymer Magnetic Solid Phase Extraction[J]. 2020, 39(6): 749-755.DOI: doi:10.3969/j.issn.1004-4957.2020.06.008.
Determination of Tetracyclines in Environmental Water Samples by High Performance Liquid Chromatography with Multi template Molecularly Imprinted Polymer Magnetic Solid Phase Extraction
A novel high performance liquid chromatography(HPLC) with magnetic solid phase extraction(MSPE) based on multi template molecularly imprinted polymer(MIP) was developed for the detection of tetracyclines in environmental water samples.The multi template MIP was prepared by sol-gel method
with mesoporous silicon magnetic graphene oxide as carrier
tetracycline
oxytetracycline
chlortetracycline and doxycycline as templates
and N-[3-(trimethoxysilyl)propyl]ethylenedi amine(KH-792) and anilinomethyl triethoxysilane(KH-42) as functional monomers
which was characterized by field emission scanning electron microscopy(SEM)
infrared spectroscopy(IR) and vibrating sample magnetometry(VSM).The method was applied in the detection of tetracycline
oxytetracycline
chlortetracycline and doxycycline in water samples.Results showed that the calibration curves for 4 tetracyclines were linear in the range of 5-50 μg/L
with their detection limits and quantitation limits of 0.67-0.95 μg/L and 2.13-3.50 μg/L
respectively.The spiked recoveries ranged from 82.7% to 103% with relative standard deviations(RSD) of 1.0%-8.8%.The proposed method could be used for the simultaneous and selective detection of these four tetracyclines in real environmental water samples.
Solid-phase Extraction of Cu(Ⅱ),Zn(Ⅱ),Cr(Ⅲ),Cd(Ⅱ) and Pb(Ⅱ) Ions in Chicken Feed Based on Polyvinylpyrrolidone Functionalized Magnetic Graphene Oxide
Determination of 3-Benzoylurea Insecticides in Fruit Juice by High Performance Liquid Chromatography with ZIF-8@Fe3O4 Based Magnetic Solid phase Extraction
Applications of Graphitic Carbon Nitride and Its Composites in Sample Pretreatment
Experimental Techniques and MethodsDetermination of a Novel Anti AIDS Drug ACC007 by High Performance Liquid Chromatography with Ultrasound assisted Ionic Liquid Dispersive Liquid-Liquid Microextraction
Effects of Three Kinds of Solid Phase Extraction Columns Purification Methods on Determination of 8 Antibiotics Residues in Dairy by High Performance Liquid Chromatography
Related Author
YU Xi-ren
DONG Yi-fan
WEI Yi-hua
HUANG Qin
ZHANG Da-wen
QIU Su-yan
郝玉兰
王曼曼
Related Institution
Key Laboratory of Agro-product Quality and Safety of Jiangxi Province
Institute for Quality & Safety and Standards of Agricultural Products Research,Jiangxi Academy of Agricultural Sciences