Determination of Bisphenol Substances in Drug and Food Homologous Products by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Combined with Accelerated Solvent Extraction and QuEChERS
|更新时间:2023-04-18
|
Determination of Bisphenol Substances in Drug and Food Homologous Products by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Combined with Accelerated Solvent Extraction and QuEChERS
曾静, 曲栗, 古淑青, 邓晓军, 伊雄海, 张晶, 丁涛, 柳菡. Determination of Bisphenol Substances in Drug and Food Homologous Products by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Combined with Accelerated Solvent Extraction and QuEChERS[J]. 2020, 39(6): 736-742.
DOI:
曾静, 曲栗, 古淑青, 邓晓军, 伊雄海, 张晶, 丁涛, 柳菡. Determination of Bisphenol Substances in Drug and Food Homologous Products by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Combined with Accelerated Solvent Extraction and QuEChERS[J]. 2020, 39(6): 736-742.DOI: doi:10.3969/j.issn.1004-4957.2020.06.006.
Determination of Bisphenol Substances in Drug and Food Homologous Products by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Combined with Accelerated Solvent Extraction and QuEChERS
A method was developed for the simultaneous determination of bisphenol substances in drug and food homologous products by ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS) combined with accelerated solvent extraction(ASE) and QuEChERS.The samples were extracted at 80 ℃ via two cycles of ASE
with acetonitrile-acetic acid-water(89∶1∶10
by volume) for 6 min
then purified by QuEChERS.11 bisphenol substances were separated on an ACQUITY UPLC HSS T3 column(2.1 mm×100 mm
1.8 μm) by gradient elution using methanol containing 0.1% formic acid and 5 mmol/L ammonium acetate containing 0.1% formic acid as mobile phases
then analyzed by MS/MS with electrospray ionization in positive and negative mode under multiple reaction monitoring(MRM) mode
finally quantified by internal standard method.There were good linear relationships for 11 bisphenol substances in the concentration range of 0.5-50.0 μg/L
with correlation coefficients(r2) not less than 0.996 0.The limits of detection(LOD) and limits of quantitation(LOQ) for 11 bisphenol substances were in the ranges of 0.1-0.5 μg/kg and 0.3-1.5 μg/kg
respectively.The recoveries at three spiked levels ranged from 72.4% to 108% with relative standard deviations(RSD) of 1.7%-15%.The proposed method was simple
rapid
high sensitive and reproducible
and it was suitable for the rapid determination of 11 bisphenol substances in drug and food homologous products.
Determination of 11 Doping Agents in Soft Capsule-type Chinese Patent Medicines by QuEChERS/Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Simultaneous Determination of 54 PPCPs in Sediment by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Pethoxamid,Pyrimisulfan and Ipfencarbazone in Grains by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Recent Advances in the Environmental Degradation Characteristics and Enzymatic Mechanisms of Biodegradable Microplastics
Effect of PLA Microplastics Combined with Cd Stress on Soil Total C,N,P Ecological Stoichiometry and Homeostasis
Related Author
ZHANG Wei
LI Chun-yu
FEI Qiao-ling
ZHAO Xue-jun
SONG Xiao-juan
CHENG Han
LI Ting-ting
DENG Hui-dan
Related Institution
School of Investigation,People's Public Security University of China
Food and Drug Testing Laboratory of Anti Doping Center of General Administration of Sport of China
Shanghai Key Laboratory of On-site Physical Evidence
Lianyungang Environmental Monitoring Center of Jiangsu Province