Determination of Five Bromine Contained Preservatives in Cosmetics by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
|更新时间:
|
Determination of Five Bromine Contained Preservatives in Cosmetics by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
潘晨, 王枚博, 吴思霖, 王欣美, 于建, 张凯, 王柯, 郑荣. Determination of Five Bromine Contained Preservatives in Cosmetics by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry[J]. 2019, 38(7): 830-834.
DOI:
潘晨, 王枚博, 吴思霖, 王欣美, 于建, 张凯, 王柯, 郑荣. Determination of Five Bromine Contained Preservatives in Cosmetics by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry[J]. 2019, 38(7): 830-834.DOI: doi:10.3969/j.issn.1004-4957.2019.07.010.
Determination of Five Bromine Contained Preservatives in Cosmetics by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
A novel high performance liquid chromatography-inductively coupled plasma mass spectrometry(HPLC-ICP-MS) was established for the determination of five bromine contained preservatives
ie.benzalkonium bromide
2 bromo 2 nitro 1
3 propanediol
5 bromo 5 nitro 1
3 dioxane
methyldibromo glutaronitrile and bromochlorophene in cosmetics.The samples were ultrasonically pretreated with methanol containing 01%formic acid.The analytes containing 79Br were separated on an Agilent Eclipse-C18 column(150 mm×46 mm
5 μm) using 01%formic acid-methanol as mobile phases by gradient elution
and then analyzed by ICP-MS with external standard method.There were good linear relationships for five analytes in the range of 05-100 mg/L with correlation coefficients(r) larger than 0999.The detection limits for five bromine contained preservatives were in range of 15-30 μg/g.Recoveries for the analytes in different spiked cosmetics matrixes ranged from 912%to 108%with relative standard deviations(n=6) of 13%-42%.The method was fast
accurate
sensitive and selective
and was suitable for the simultaneous determination of five bromine contained preservatives in cosmetics.
Determination of Distearyl Dimethyl Ammonium Chloride in Cosmetics by High Performance Liquid Chromatography-Evaporative Light Scattering Detector
Determination of Ultra-trace Migration of Hexavalent Chromium in Toy Materials by Online Enrichment/High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
Gold Nanoparticle Modified Polymer Monolithic Microextraction Combined with ICP-MS for On-line Analysis of Trace Elements in Cells
Determination of 33 Harmful Volatile Organic Solvents in Cosmetics by Headspace-Gas Chromatography-Mass Spectrometry
Determination of 81 Fragrance Components in Cosmetics by Gas Chromatography-Mass Spectrometry