魏轩, 王琰, 王兆彦, 蒲巧生. Improvement of Reliability for Microchip Electrophoresis with Pinched Sample Injection Through Branched Microchannels[J]. 2019, 38(5): 552-557.
DOI:
魏轩, 王琰, 王兆彦, 蒲巧生. Improvement of Reliability for Microchip Electrophoresis with Pinched Sample Injection Through Branched Microchannels[J]. 2019, 38(5): 552-557.DOI: doi:10.3969/j.issn.1004-4957.2019.05.008.
Improvement of Reliability for Microchip Electrophoresis with Pinched Sample Injection Through Branched Microchannels
Microchip electrophoresis has shown its potential of application in many fields
but its utilization in real world is still limited.To achieve a successful separation on a microchip through electrophoresis
many details have to be carefully taken into account
such as the liquid levels of each reservoir
the exact location of each electrode etc.
skillful operation is therefore required.In this paper
branched microchannels were introduced at the inlet end of the sampling channel and the outlet of the separation channel of traditional microchips for electrophoresis with a cross configuration.Additional reservoirs were made
and the liquid levels of these two reservoirs were lower than that of the sample reservoir and the buffer waste reservoir
maintaining continuous refreshing at the branched points through siphoning.With 2 fluorescein isothiocyanate labeled organophosphorus herbicides
ie.glyphosate and glufosinate
and a degradation product
(aminomethyl)phosphonic acid
the applicability of the proposed microchip was investigated.Results showed that with this kind of microchips
several improvements could be achieved.Firstly
the injection time for the consecutive analysis with pinched injection could be shortened due to its effectiveness to prevent the dilution of the sample in the sampling channel by the buffer during the separation periods.Secondly
the baseline drift due to the entrance of separation waste back to the detection point during the injection periods could be effectively eliminated.Thirdly
the repeatability of the consecutive analysis was therefore significantly improved
120 times of consecutive injection gave a relative standard deviation(RSD) of peak height as low as 056%(calculated for(aminomethyl)phosphonic acid) with replenishing of the buffer and sample every 40 injections.More importantly
by using the proposed microchip
a pre separation could be performed by controlling the injection time.Components migrating slower in the sample could be excluded from the injection into the separation channel
making it possible to get rid of most of sample matrix by tuning the separation condition to make analytes migrate faster than the matrix components.This kind of pre separation could simplify the electropherogram and avoid possible contamination of the separation microchannel
which is also beneficial to the reliability of microchip electrophoresis.
Determination of Hemoglobin in Single Human Red Blood Cell by Microchip Electrophoresis with Chemiluminescence Detection
Analysis of Adsorption Interaction Mechanism between Polyvinyl Chloride Microplastics and Phenanthrene Derivatives Based on Two-dimensional Correlation Spectroscopy
Non-targeted Screening Analysis of Biodegradable Plastics Components Based on Chromatography-Mass Spectrometry
Definition Clarification and Detection Reliability Analysis of Environmental Micro/Nanoplastics
Detection of Micro/Nanoplastics in Tea Bag Leachate Using Cloud Point Extraction Combined with Matrix-assisted Laser Desorption Ionization Time-of-flight Mass Spectrometry