HE Zhang-jin,DU Yu-ying,LU Li-ping.Sensitive Detection of Telomerase Activity Based on a G-quadruplex Electrochemiluminescent Biosensor[J].Journal of Instrumental Analysis,2024,43(07):963-970.
HE Zhang-jin,DU Yu-ying,LU Li-ping.Sensitive Detection of Telomerase Activity Based on a G-quadruplex Electrochemiluminescent Biosensor[J].Journal of Instrumental Analysis,2024,43(07):963-970. DOI: 10.12452/j.fxcsxb.24041803.
Sensitive Detection of Telomerase Activity Based on a G-quadruplex Electrochemiluminescent Biosensor
The analysis and detection of telomerase activity is important for cancer diagnosis,prognosis,and treatment. In this study,an electrochemiluminescence(ECL) biosensor was constructed for sensitive detection of telomerase activity in cancer cells using a metal complex-targeted luminescent probe[Ir(ppy)
2
(pip)]PF
6
for G-quadruplex(G4) DNA. Primer DNA was first assembled on the electrode surface and then co-incubated with telomerase extracted from cancer cells. The active telomerase generated telomeric repeats at the end of the primer to form the G4 structure,and then[Ir(ppy)
2
(pip)]PF
6
bound to the extended sequence by targeting with G4. The results showed that the ECL signal of[Ir(ppy)
2
(pip)]PF
6
showed a positive correlation with telomerase activity,and the ECL intensity of the sensor showed a good linear correlation with the concentration of cancer cells in the range of 10-5×10
5
cell/mL,with the limit of detection(LOD) of 3 cell/mL. The experiments also demonstrated that the sensor had good stability,applicability,anti-interference ablity,and reproducibility. Finally,the sensor was used for the determination of telomerase activity in real human serum and urine samples,and satisfactory results were also obtained.
De-Jesus B B,Blasco M A. Trends Genet.,2013,29(9):513-520.
Wang Y,Sušac L,Feigon J. Cell. Mol. Life Sci.,2019,11(12):a032383.
Abraham-Punnoose J,Ma Y,Hoque M E,Cui Y,Sasaki S,Guo A H,Nagasawa K,Mao H. Biochem.,2018,57(51):6946-6955.
Ling P,Lei J,Jia L,Ju H. Chem. Commun.,2016,52(6):1226-1229.
Greider C W,Blackburn E H. Nature,1989,337(6205):331-337.
Vukašinović A R,Kotur-Stevuljević J M,Mlakar V,Sopić M D,Cvetković Z P,Petković M R,Spasojević-Kalimanovska V V,Bogavac-Stanojević N B,Ostanek B. Scan. J. Clin. Lab. Inv.,2019,79(3):188-193.
Shan S,Li J,Han G,Zhang R,Liu Z,Zhang Z. Analyst,2022,147(11):2405-2411.
Zong S,Wang Z,Chen H,Cui Y. Small,2013,9(24):4215-4220.
Ravalli A,Voccia D,Palchetti I,Marrazza G. Biosensors-Basel,2016,6(3):39.
G-quadruple/Hemin DNAzyme-based Visual Detection of the Folding Structure Formed by d(GGA) Trinucleotide Repeats
Synthesis and Characterization of a Long-term Stable Lead-dependent DNAzyme
Aptamer Electrochemiluminescence Sensor for Sensitive Detection of Chloramphenicol
Application of Aptamer Biosensor in Detection of Aflatoxin B1
Related Author
YOU Xin
HE Rong-rong
YAN Xing-he
NAN Yin-xing
CHANG Tian-jun
BING Tao
YOU Xin
HE Rong-rong
Related Institution
Hangzhou Institute of Medicine(HIM),Chinese Academy of Sciences,Hangzhou
Institute of Resources and Environment,Henan Polytechnic University,Jiaozuo
Hangzhou Institute of Medicine(HIM),Chinese Academy of Sciences
Institute of Resources and Environment,Henan Polytechnic University
Hunan Provincial Key Laboratory of Water Treatment Functional Materials,Hunan Province Engineering Research Center of Electroplating Wastewater Reuse Technology,College of Chemistry and Materials Engineering,Hunan University of Arts and Science