Simultaneous Determination of 23 Bisphenol Analogs and Their Halogenated Derivatives in Urine and Serum by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:2023-04-18
|
Simultaneous Determination of 23 Bisphenol Analogs and Their Halogenated Derivatives in Urine and Serum by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 39, Issue 6, Pages: 715-721(2020)
作者机构:
1. 北京市疾病预防控制中心食物中毒诊断溯源技术北京市重点实验室
2. 中国检验检疫科学研究院综合检测中心
3. 天津科技大学食品工程与生物技术学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of 23 Bisphenol Analogs and Their Halogenated Derivatives in Urine and Serum by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 39(6):715-721(2020)
DOI:
Simultaneous Determination of 23 Bisphenol Analogs and Their Halogenated Derivatives in Urine and Serum by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 39(6):715-721(2020)DOI:
Simultaneous Determination of 23 Bisphenol Analogs and Their Halogenated Derivatives in Urine and Serum by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
An ultra high performance liquid chromatography-tandem mass spectrometric(UPLC-MS/MS) method was developed for the simultaneous determination of 23 bisphenol analogs and their halogenated derivatives(BPs) in urine and serum based on derivatization of pyridine-3-sulfonyl chloride.Urine samples were extracted by liquid-liquid extraction with ethyl acetate,while serum samples were extracted with acetonitrile and followed by PRiME HLB cartridge purification.After derivatization with pyridine-3-sulfonyl chloride,the extracts were separated on an ACQUITY UPLC BEH C18(2.1 mm×100 mm,1.7 μm) column with acetonitrile and water containing 0.1% formic acid as mobile phases,and determined by UPLC-MS/MS with electrospray ionization(ESI) in positive ion mode.There were good linear relationships for 23 BPs in both urine and serum samples in the range of 0.005-100 μg/L,with their limits of detection between 0.002 μg/L and 0.030 μg/L ,limits of quantitation between 0.005 μg/L and 0.100 μg/L.Average recoveries ranged from 76.6% to 122%,with relative standard deviations(RSD) of 0.60%-14%.The method was applied in the analysis of BPs in 20 urine samples and 20 serum samples.The method could meet the requirements for simultaneous determination of 23 BPs in urine and serum samples with low sample consumption and high sensitivity.
关键词
双酚类化合物尿液血清吡啶-3-磺酰氯超高效液相色谱-串联质谱(UPLC-MS/MS)
Keywords
bisphenol analogs and their halogenated derivativesurineserumpyridine 3 sulfonyl chlorideultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)
In Situ Synthesis of Au/Foam Nickel Magnetic Substrate for Rapid Detection of Immunosuppressive Drug Metabolites in Serum by Using Surface Enhanced Raman Scattering Spectroscopy
Determination of Free Thyroid Hormones in Serum by Gel Filtration Chromatography Combined with Liquid Chromatography-Tandem Mass Spectrometry
Study on the Method for the Identification of Sulfanilamide,Quinolone and Tetracycline in Urine by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
Related Author
No data
Related Institution
College of Chemistry and Materials Science,Shanghai Normal University
Chengdu Institute of Biology,Chinese Academy of Sciences
Chengdu Institute of Organic Chemistry,Chinese Academy of Sciences
University of Chinese Academy of Sciences
Beijing Center for Disease Control and Prevention,Beijing Center for Preventive Medicine Research