Determination of Emission Quantity of Volatile Aldehydes in Adhesive by High Performance Liquid Chromatography with Environmental Chamber
|更新时间:2023-05-25
|
Determination of Emission Quantity of Volatile Aldehydes in Adhesive by High Performance Liquid Chromatography with Environmental Chamber
Vol. 39, Issue 3, Pages: 396-400(2020)
作者机构:
上海海关工业品与原材料检测技术中心
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Emission Quantity of Volatile Aldehydes in Adhesive by High Performance Liquid Chromatography with Environmental Chamber. [J]. 39(3):396-400(2020)
DOI:
Determination of Emission Quantity of Volatile Aldehydes in Adhesive by High Performance Liquid Chromatography with Environmental Chamber. [J]. 39(3):396-400(2020)DOI:
Determination of Emission Quantity of Volatile Aldehydes in Adhesive by High Performance Liquid Chromatography with Environmental Chamber
A high performance liquid chromatographic(HPLC) method with environmental chamber was developed for the determination of emission quantity of volatile aldehydes in adhesive.Adhesive was spread on the surface of support which was then placed at the center of an environmental chamber.A sufficient volume of environmental chamber air was drawn at an appropriate flow through silicagel tubes impregnated with 2,4-dinitrophenylhydrazine(DNPH) reagent.Aldehydes reacted with DNPH to form non volatile dinitrophenylhydrazones which were desorbed with acetonitrile,and then analyzed by HPLC.The separation was performed on a Kromasil KR100-5 C18 column(250 mm×4.6 mm,5 μm) by gradient elution with acetonitrile and water as mobile phases at a flow rate of 1.0 mL/min.The column temperature was 40 ℃,and the detection wavelength was 360 nm.Results showed that 13 aldehydes had good linear relationships(r≥0.997 7),and the limits of detection(LOD) were in the range of 1.6-20.8 μg/m3.Recoveries for the analytes ranged from 86.3% to 115% with relative standard deviations(RSD) of 3.5%-8.6%.With good precision and accuracy,the method provided a new approach for determination of emission quantity of volatile aldehydes in adhesive after application.
Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water by HPLC with Stir Bar Adsorption Extraction Based on Covalent Organic Framework Coating
Polydopamine Modified Titanium Dioxide Nano/Submicro Particles Coating for Solid Phase Microextraction of Phthalic Acid Esters
Preparation of a Covalent Organic Framework TpBD-(NH2)2-D-(-)-α-phenylglycine and Its Application Used as Chiral Stationary Phase for High Performance Liquid Chromatography
Determination of 12 Saccharides in Honey by Ultra High Performance Liquid Chromatography Coupled with Evaporative Light Scattering Detection
Related Author
No data
Related Institution
School of Chemistry and Chemical Engineering,Lanzhou City University
Provincial Key Laboratory of Gansu Higher Education for City Environmental Pollution Control
Provincical Key Laboratory of Gansu Higher Education for City Environmental Pollution Control
College of Chemistry and Chemical Engineering,Qinghai Minzu University
Key Lab of Resource Chemistry&Eco-environmental Protection in Qinghai-Tibet Plateau, State Ethnic Affairs Committee,Qinghai Minzu University