Analysis of Macrolide Antibiotics in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry Based on Solid Phase Extraction
|更新时间:2023-04-18
|
Analysis of Macrolide Antibiotics in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry Based on Solid Phase Extraction
Vol. 39, Issue 7, Pages: 874-880(2020)
作者机构:
1. 江苏省农业科学院农产品质量安全与营养研究所
2. 省部共建国家重点实验室培育基地-江苏省食品质量安全重点实验室
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Analysis of Macrolide Antibiotics in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry Based on Solid Phase Extraction. [J]. 39(7):874-880(2020)
DOI:
Analysis of Macrolide Antibiotics in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry Based on Solid Phase Extraction. [J]. 39(7):874-880(2020)DOI:
Analysis of Macrolide Antibiotics in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry Based on Solid Phase Extraction
A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS) was developed for the simultaneous determination of seven macrolide antibiotics,ie.tilmicosin,roxithromycin,spiramycin,tylosin,erythromycin,clarithromycin and azithromycin in additive premix,concentrate supplement,complete feed and concentrated feed.The samples were extracted with 1% ammoniated acetonitrile solution,followed by Oasis PRiME HLB solid phase extraction for further purification.The analytes were separated on an ACQUITY UPLC BEH C18 column(2.1 mm×100 mm,1.7 μm) by gradient elution using 0.1% formic acid solution and acetonitrile as mobile phases,then analyzd by MS/MS with electrospray ionization in positive mode,and quantified by external standard method.Results showed that there were good linear relationships for 3 target analytes,ie.tilmicosin,spiramycin and erythromycin in the concentration range of 0.5-50 μg/L(r2>0.99) and for the other 4 target analytes in the range of 0.25-50 μg/L(r2>0.99).The limits of detection and the limits of quantitation were in the ranges of 1.25-2.5 μg/kg and 2.5-5.0 μg/kg,respectively.At three spiked levels of 5,10 and 50 μg/kg,the average recoveries for target compounds ranged from 61.4% to 103% with relative standard deviations of 0.43%-15%.The developed method is simple,rapid,sensitive and low matrix interference,and it is suitable for the routine supervision and quantitative detection of macrolide antibiotics in different feeds.
关键词
大环内酯类药物饲料高效液相色谱-串联质谱固相萃取
Keywords
macrolide antibioticsfeedhigh performance liquid chromatography-tandem mass spectrometrysolid phase extraction
Simultaneous Determination of Chloramphenicol,Thiamphenicol and Florfenicol Residues in Feed by High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Thiencarbazone-methyl and Its Metabolites in Different Environmental Matrixes by Liquid Chromatography- Tandem Mass Spectrometry
Simultaneous Determination of 12 Organophosphate Esters in Soil by Solid Phase Extraction/High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of 53 Semi-volatile Organic Compounds in Solid Waste by Gas Chromatography-Mass Spectrometry with Microwave Extraction and Solid Phase Extraction Column Purification
Determination of New Red in Beverages and Prepared Wines by HPLC-MS/MS with Solid Phase Extraction Based on Metal Organic Frameworks UiO-66-NH2
Related Author
No data
Related Institution
淮安出入境检验检疫局
江苏出入境检验检疫局动植物与食品检测中心
Key Laboratory of Pesticide Environmental Assessment and Pollution Control,Ministry of Environmental Protection,Nanjing Institute of Environmental Sciences,Ministry of Ecology and Environment of the People’s Republic of China
College of Carbon Neutral Modern Industry,College of Environmental and Resource Science,Fujian Normal University
Fujian Key Laboratory of Pollution Control and Resource Reuse