Electrochemical Behaviour and Determination of Paraquat on the Glassy Carbon Electrode Modified with Montmorillonite and Ionic Liquid
|更新时间:
|
Electrochemical Behaviour and Determination of Paraquat on the Glassy Carbon Electrode Modified with Montmorillonite and Ionic Liquid
Vol. 30, Issue 1, Pages: 48-52(2011)
作者机构:
西华师范大学化学化工学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Electrochemical Behaviour and Determination of Paraquat on the Glassy Carbon Electrode Modified with Montmorillonite and Ionic Liquid. [J]. 30(1):48-52(2011)
DOI:
Electrochemical Behaviour and Determination of Paraquat on the Glassy Carbon Electrode Modified with Montmorillonite and Ionic Liquid. [J]. 30(1):48-52(2011)DOI:
Electrochemical Behaviour and Determination of Paraquat on the Glassy Carbon Electrode Modified with Montmorillonite and Ionic Liquid
A novel PTA-MMT and[BMIM]PF6 modified glassy carbon electrode(PTA-MMT-[BMIM]PF6/GCE) was prepared and successfully used for the determination of paraquat(PQ).The modified film was characterized by infared(IR) spectrometry.The charge transfer resistance of PQ on PTA-MMT-[BMIM]PF6/GCE was the lowest by comparing the nyquist plots of the electrode before and after modification.The cyclic voltammetric behavior of PQ on modified electrode was studied. The results showed that,in pH 80 phosphate buffer solution(PBS),two pairs of redox peaks were observed on the modified electrode.The oxidation peak current was linear to scan rates in the range of 40-360 mV?s-1,indicating that the electrode process of PQ was controlled by absorption.The reaction electronic number and active area of PQ on PTA-MMT-[BMIM]PF6/GCE were obtained to be 2 and 0064 4 cm2,respectively.The effects of modifier dosage,buffer solution types and pH values for the determination of PQ were discussed.Under the optimized conditions,the correlation between peak current(Ipa) and PQ concentration was studied by square wave voltammetry,and a good linear relationship was obtained over PQ concentration in the range of 50×10-7-25×10-4 mol?L-1.The linear equation was Ipa(μA)=-1024-23683c(r=0999 3) and the detection limit was 207×10-7 mol?L-1.The spiked recoveries were in the range of 93%-104%.The modified electrode exhibited good repeatability and stability.
ReviewsSeparation Mechanism and Application of Aqueous Biphasic Systems Based on Ionic Liquids
Experimental Techniques and MethodsDetermination of a Novel Anti AIDS Drug ACC007 by High Performance Liquid Chromatography with Ultrasound assisted Ionic Liquid Dispersive Liquid-Liquid Microextraction
Analysis of Benzoic Acid and Sorbic Acid by Reversed phase Chromatography with Imidazolium Ionic Liquid as Mobile Phase Additive
Electrochemical Behavior and Determination of Bisphenol A on the Gold Nanoparticles-Ionic Liquid Modified Electrode
Electrochemical Behavior and Determination of Hydroquinone on Silver/Treated Montmorillonite Modified Glassy Carbon Electrode