Analysis of Corticosteroids in Cosmetics by Reversed Microemulsion Electrokinetic Chromatography with 1 Butyl 3 methylimizolium Tetrafluoborate Ionic Liquid as Additive
|更新时间:
|
Analysis of Corticosteroids in Cosmetics by Reversed Microemulsion Electrokinetic Chromatography with 1 Butyl 3 methylimizolium Tetrafluoborate Ionic Liquid as Additive
Vol. 30, Issue 2, Pages: 203-206(2011)
作者机构:
1. 江南大学化学与材料工程学院
2. 郑州轻工业学院材料与化学工程学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Analysis of Corticosteroids in Cosmetics by Reversed Microemulsion Electrokinetic Chromatography with 1 Butyl 3 methylimizolium Tetrafluoborate Ionic Liquid as Additive. [J]. 30(2):203-206(2011)
DOI:
Analysis of Corticosteroids in Cosmetics by Reversed Microemulsion Electrokinetic Chromatography with 1 Butyl 3 methylimizolium Tetrafluoborate Ionic Liquid as Additive. [J]. 30(2):203-206(2011)DOI:
Analysis of Corticosteroids in Cosmetics by Reversed Microemulsion Electrokinetic Chromatography with 1 Butyl 3 methylimizolium Tetrafluoborate Ionic Liquid as Additive
A reversed microemulsion electrokinetic chromatographic(MEEKC) method was developed for the separation of three corticosteroids,including hydrocortisone,prednisone and hydrocortisone acetate by using 1 butyl 3 methylimizolium tetrafluoborate(BMIM-BF4) ionic liquid(IL) as additive.The effects of experimental conditions such as BMIM-BF4 concentration and pH value on separation efficiency were investigated.The optimized conditions were as follows:24% sodium dodecyl sulfate(SDS),66% 1 butanol,05% n octane,35 mmol/L BMIM-BF4,pH 22 20 mmol/L NaH2PO4,an applied voltage of -20 kV and a detection wavelength of 250 nm.Under the optimized conditions,the calibration curves were linear in the range of 5-400,5-400,5-800 mg?L-1 for hydrocortisone,prednisone and hydrocortisone acetate with detection limits(S/N=3) of 09,09,12 mg/L,respectively.The RSDs(n=3) were less than 43%.The average spiked recoveries were 102%,97% and 94%,respectively.The results showed that the resolution of the IL-MEEKC method for the separation of hydrocortisone,prednisone and hydrocortisone acetate was higher than that of the conventional MEEKC method.The proposed method was simple,rapid and effective,and could be used for the quality control of cosmetics.
Determination of 8 Prohibited Tidine Drugs in Cosmetics by Ultra High Performance Liquid Chromatography-Triple Quadrupole Mass Spectrometry
Determination of Seven Dimethylcyclosiloxanes in Cosmetics by Gas Chromatography-Tandem Mass Spectrometry
Determination of Perfluorinated and Polyfluoroalkyl Substances in Cosmetics by Ultra High Performance Liquid Chromatography- Tandem Mass Spectrometry
Determination of Fifteen N-nitrosamine Compounds in Cosmetics by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Related Author
No data
Related Institution
Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology,Guangdong Provincial Engineering Research Center for Quality and Safety of Traditional Chinese Medicine,Institute of Analysis,Guangdong Academy of Sciences(China National Analytical Center,),Guangzhou
Guangzhou Institute for Drug Control
Institute of Analysis,Guangdong Academy of Sciences(China National Analytical Center,Guangzhou),Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology,Guangdong Provincial Engineering Research Center for Quality and Safety of Traditional Chinese Medicine
Guangdong Institute for Drug Control,National Medical Products Administration Key Laboratory for Safety Risk Assessment of Cosmetics
Guangzhou Quality Supervision and Testing Institute,National Quality Supervision and Testing Center for Cosmetics(),Guangzhou