A high performance liquid chromatographic(HPLC) method was developed for the determination of antioxidant D in pressure sensitive adhesive and its products.The sample was dissolved with ethyl acetate,then precipitated by methanol.The extract was centrifugally separated for 5 min at a speed of 3 000 r/min.After filtrated with filter membrane,the supernatant was separated on a C18 column by isocratic elution using acetonitrile-water as mobile phase at a flow rate of 0.5 mL/min,and determined by HPLC with diode-array detector(DAD)at 310 nm,quantified by the external standard method.The conditions of sample pretreatment and chromatographic separation were optimized,and the confirmatory method of mass spectrometry used to quantitatively determine antioxidant D in the sample was established.Under the optimal conditions,the method showed good linearities between peak areas and the contents in the ranges of 0.01-1 mg/L and 1-100 mg/L for antioxidant D,with a limit of quantitation of 1 mg/kg.The established method was applied in the determination of antioxidant D in emulsion-type pressure-sensitive adhesive,hotmelt-type pressure-sensitive adhesive and solvent-type pressure-sensitive adhesive,and the spiked recoveries ranged from 96% to 100% with relative standard deviations(RSDs) of 1.1%- 3.1%.The results indicated that this method was reliable,sensitive and repeatable,and could meet the requirement for analysis of antioxidant D in the pressure sensitive adhesive and its products.
Detection of Seven Quinolones in Honey by High Performance Liquid Chromatography with Effervescent Assisted Liquid Phase Microextraction
Simultaneous Determination of 19 Organic Antibacterial Agents in Tissue Paper and Paper Products by High Performance Liquid Chromatography
Simultaneous Determination of Three Diabetic Drugs in Urine by High Performance Liquid Chromatography
Simultaneous Determination of Vanillin and o Vanillin by High Performance Liquid Chromatography
Simultaneous Determination of Ten Synthetic Colours in Ice-cream by High Performance Liquid Chromatography
Related Author
No data
Related Institution
Institute of Agricultural Quality Standards and Testing Technology,Tianjin Academy of Agricultural Sciences
Tianjin Key Laboratory of Agricultural Animal Breeding and Healthy Husbandry,College of Animal Science and Veterinary Medicine,Tianjin Agricultural University
Guangdong Testing Institute of Product Quality Supervision, Shunde