Application of Anthraquinone Derivative for Determination of Trace Hg2+ by Solid Substrate-Room Temperature Phosphorescence Quenching Method
|更新时间:
|
Application of Anthraquinone Derivative for Determination of Trace Hg2+ by Solid Substrate-Room Temperature Phosphorescence Quenching Method
Vol. 30, Issue 4, Pages: 413-417(2011)
作者机构:
1. 漳州市产品质量检验所
2. 漳州师范学院化学与环境科学系
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Application of Anthraquinone Derivative for Determination of Trace Hg2+ by Solid Substrate-Room Temperature Phosphorescence Quenching Method. [J]. 30(4):413-417(2011)
DOI:
Application of Anthraquinone Derivative for Determination of Trace Hg2+ by Solid Substrate-Room Temperature Phosphorescence Quenching Method. [J]. 30(4):413-417(2011)DOI:
Application of Anthraquinone Derivative for Determination of Trace Hg2+ by Solid Substrate-Room Temperature Phosphorescence Quenching Method
2,3-Dihydro-9,10-dihydroxy-1,4-anthraquinone(R)was synthesized and characterized by 1H NMR,IR,MS and UV-Vis spectrometry.Based on the facts that R can emit intense and stable solid substrate-room temperature phosphorescence(SS-RTP) on solid substrate,and α,α dipyridine can activate Hg2+ to catalyze the reaction of H2O2 oxidizing R to form non phosphorescence compound, a new solid substrat-room temperature phosphorescence quenching method was established for the determination of trace mercury.Under the optimum condition,the relationship between the ΔIp of the emitting intensity and 1.60-160 fg/spot Hg2+(corresponding concentration:0.004 0-0.40 μg/L,sample volume:0.4 μL/spot) conformed to Beer law.The regression equation was ΔIp=11.56+0.549 2 m(fg/spot) (r=0.999 1).The limit detection was 0.26 fg/spot(corresponding Hg2+ concentration:6.5× 10-10 g/L).The spiked recoveries were in the range of 97%-103% with RSDs of 2.3%-4.1%.The RSDs(n=11) of 0.004 0 μg/L and 0.40 μg/L Hg2+ were 2.6% and 4.1%,respectively.The method showed good repeatability,sensitivity and high precision.It was applied in the determination of trace mercury (Ⅱ) in real samples with satisfactory results.
Detection of Mercury Ions in Water by Nitrogen and Sulfur-doped Fluorescent Carbon Quantum Dots
Detection of Mercury by a Label-free Aptamer-based Fluorescent Assay
Simultaneous Determination of 35 Sex Hormones in Cosmetics by Ultra performance Liquid Chromatography-Tandem Mass Spectrometry
Study on Determination of Glucoside by Gas Chromatography with Electron Capture Detector
Determination of Amantadine Hydrochloride in Amantadine Hydrochloride Tablets by Microfluidic Chip Method