Determination of Hexafluorophosphate Ionic Liquid Anion by Reversed-phase Ion pair Chromatography Coupled with Direct Conductivity Detection
|更新时间:
|
Determination of Hexafluorophosphate Ionic Liquid Anion by Reversed-phase Ion pair Chromatography Coupled with Direct Conductivity Detection
Vol. 31, Issue 5, Pages: 530-534(2012)
作者机构:
哈尔滨师范大学化学化工学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Hexafluorophosphate Ionic Liquid Anion by Reversed-phase Ion pair Chromatography Coupled with Direct Conductivity Detection. [J]. 31(5):530-534(2012)
DOI:
Determination of Hexafluorophosphate Ionic Liquid Anion by Reversed-phase Ion pair Chromatography Coupled with Direct Conductivity Detection. [J]. 31(5):530-534(2012)DOI:
Determination of Hexafluorophosphate Ionic Liquid Anion by Reversed-phase Ion pair Chromatography Coupled with Direct Conductivity Detection
A reversed-phase ion-pair chromatographic method using direct conductivity detection was developed for the determination of hexafluorophosphate(PF-6) ionic liquid anion.Chromatographic separation was performed on a Diamonsil C18 reversed-phase column using ion-pair reagent-citric acid-acetonitrile as mobile phase.The effects of ion-pair reagent,volume fraction of acetonitrile,pH and column temperature on the retention factor and separation of PF-6 were investigated.The mechanism of retention in the separation was discussed.The optimized chromatographic conditions for the determination of PF-6 were using 0.05 mmol/L tetrabutylammonium hydroxide(TBAH)-0.038 mmol/L citric acid-35% acetonitrile(pH 5.5) as mobile phase,at a flow rate of 1.0 mL/min and a column temperature of 40 ℃.Under the optimal conditions,the retention time of PF-6 was less than 15 min and the baseline separation of PF-6 was achieved without any interference by other common anions(Cl-,NO-3,F-,Br-,SO2-4 and BF-4).The detection limit(S/N=3) for PF-6 was 0.25 mg/L.The good linear relationship was obtained between chromatographic peak area and concentration of PF-6 in the range of 0.5-100.0 mg/L.The relative standard deviations (RSD,n=5) of chromatographic peak area and retention time were 0.17% and 0.15%,respectively.The proposed method was applied in the determination of PF-6 in ionic liquids of 1-butyl-3-methylimidazolium hexafluorophosphate and 1-propyl-2,3- dimethylimidazolium hexafluorophosphate.The spiked recoveries of PF-6 were 99% and 104%,respectively.The good linearity and repeatability of the method could meet the requirements for the quantitative analysis of PF-6 in ionic liquids.The method is simple,accurate,reliable and practical.
ReviewsSeparation Mechanism and Application of Aqueous Biphasic Systems Based on Ionic Liquids
Experimental Techniques and MethodsDetermination of a Novel Anti AIDS Drug ACC007 by High Performance Liquid Chromatography with Ultrasound assisted Ionic Liquid Dispersive Liquid-Liquid Microextraction
Analysis of Benzoic Acid and Sorbic Acid by Reversed phase Chromatography with Imidazolium Ionic Liquid as Mobile Phase Additive
Analysis of Pyridinium Ionic Liquid Cations by Ion Chromatography with Direct Conductivity Detection
Electrochemical Behaviour and Determination of Paraquat on the Glassy Carbon Electrode Modified with Montmorillonite and Ionic Liquid