Electrocatalytic Oxidation of Glutathione at nano-TiO2-Caffeic Acid Modified Carbon Paste Electrode and Its Electrochemical Determination
|更新时间:
|
Electrocatalytic Oxidation of Glutathione at nano-TiO2-Caffeic Acid Modified Carbon Paste Electrode and Its Electrochemical Determination
Vol. 30, Issue 8, Pages: 897-901(2011)
作者机构:
宁夏大学化学化工学院能源化工重点实验室.2.宁夏医科大学高等卫生职业技术学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Electrocatalytic Oxidation of Glutathione at nano-TiO2-Caffeic Acid Modified Carbon Paste Electrode and Its Electrochemical Determination. [J]. 30(8):897-901(2011)
DOI:
Electrocatalytic Oxidation of Glutathione at nano-TiO2-Caffeic Acid Modified Carbon Paste Electrode and Its Electrochemical Determination. [J]. 30(8):897-901(2011)DOI:
Electrocatalytic Oxidation of Glutathione at nano-TiO2-Caffeic Acid Modified Carbon Paste Electrode and Its Electrochemical Determination
The electrocatalytic oxidation behaviors and electrochemical determination of glutathione(GSH) were investigated at nano-TiO2-caffeic acid modified carbon paste electrode(nano-TiO2-CFA/CPE).The experimental results indicated that GSH showed a very poor electrochemical response at CPE and nano-TiO2/CPE,but GSH at nano-TiO2-CFA/CPE exhibited a better electrocatalytic activity than that at CFA/CPE.The kinetic properties of GSH were discussed at nano-TiO2-CFA/CPE by cyclic voltammetr(CV)and chronoamperometry(CA).The catalytic oxidation peak current of GSH versus its concentration had a good linear relationship in the concentration range of 9.0×10-6 -1.0×10-3 mol·L-1 with a correlation coefficient of 0.997 5,and a detection limit of 8.85×10-7 mol·L-1 by linear sweep voltammetry(LSV).The method was applied in the determination of GSH contents in real samples with satisfactory results.
Preparation of a Novel Peroxide-like Nanozyme NC@MIL-100(Fe) and Its Application in Biothiols Analysis
Determination of Caffeic Acid and Chlorogenic Acid in Honeysuckle by Field-amplified Sample Injection and Sweeping-micellar Electrokinetic Chromatography
Determination of Magnolol,Chlorogenic Acid,Caffeic Acid in Qinggan Lidan Oral by Capillary Electrophoresis with LVSS-Reverse Current Flow Accumulation-CZE
Glucose Biosensor Based on the Chitosan /Glutathione Composite Film
Electrochemical Behaviors of Meloxicam at AB and [BnMIM]PF6 Modified Carbon Paste Electrode and Its Electrochemical Determination
Related Author
No data
Related Institution
Shanghai Key Laboratory of Functional Materials Chemistry,School of Chemistry and Molecular Engineering, East China University of Science and Technology