Simultaneous Determination of Spiramycin and Neospiramycin in Antibiotic Production Wastewater by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:2023-05-18
|
Simultaneous Determination of Spiramycin and Neospiramycin in Antibiotic Production Wastewater by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 31, Issue 1, Pages: 90-95(2012)
作者机构:
1. 山东大学环境科学与工程学院
2. 中国科学院生态环境研究中心环境水质学国家重点实验室
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of Spiramycin and Neospiramycin in Antibiotic Production Wastewater by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 31(1):90-95(2012)
DOI:
Simultaneous Determination of Spiramycin and Neospiramycin in Antibiotic Production Wastewater by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 31(1):90-95(2012)DOI:
Simultaneous Determination of Spiramycin and Neospiramycin in Antibiotic Production Wastewater by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
An ultra performance liquid chromatography-tandem mass spectrometric(UPLC-MS/MS) method was developed for the simultaneous determination of spiramycin(e.g.spiramycin Ⅰ,SPM-Ⅰ) and neospiramycin(e.g.neospiramycin Ⅰ,NSPM-Ⅰ) residues in antibiotic production wastewater.The factors influencing the recoveries of antibiotics,including organic extractant type,water sample pH value,extraction time and ratio of water sample to organic extractant,were investigated.The target compounds were separated on an ACQUITY UPLC BEH C18 column(100 mm × 2.1 mm i.d.,1.7 μm) by gradient elution using 0.1% formic acid(A) and acetonitrile(B) as mobile phases at a flow rate of 0.2 mL/min.The qualification and quantification of target antibiotics were carried out by MS/MS with positive electrospray ionization under multiple reaction monitoring(MRM) mode.The calibration curves were linear over an antibiotic concentration range of 0.02-1.00 mg/L with correlation coefficients(r2) more than 0.999.The recoveries of antibiotics ranged from 70% to 88% with relative standard deviations(RSD,n=6) less than 10%.The detection limits(S/N=3) for SPM-Ⅰ and NSPM-Ⅰ were 0.03 μg/L and 0.06 μg/L,respectively.The developed method was applied in the determination of antibiotic production wastewater from a pharmaceutical manufacturing factory in Wuxi City,with SPM-Ⅰ of (115.6±2.7) mg/L and NSPM-Ⅰ of(5.3±0.4) mg/L.
关键词
抗生素生产废水螺旋霉素新螺旋霉素超高效液相色谱-串联质谱法
Keywords
antibiotic production wastewaterspiramycinneospiramycinultra performance liquid chromatography-tandem mass spectrometry
Rapid Determination of 49 Kinds of Illegally added Chemical Drugs in Chinese Patent Medicine by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Detection of Sodium Trithiocyanurate in Wheat Flour and Flour Additives by Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry with Pass through SPE Cleanup
Three-phase Hollow Fiber Membrane Liquid Phase Microextraction/Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry for Determination of Benzoic and Sorbic Acid in Drinks
Simultaneous Determination of 14 Macrolide Drugs Residues in Pork Samples by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Solid Phase Extraction