Determination of 19 Pesticide Residues in Tea Using QuEChERS Extraction and High-performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry
|更新时间:
|
Determination of 19 Pesticide Residues in Tea Using QuEChERS Extraction and High-performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry
Vol. 30, Issue 9, Pages: 990-995(2011)
作者机构:
广东出入境检验检疫局
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of 19 Pesticide Residues in Tea Using QuEChERS Extraction and High-performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry. [J]. 30(9):990-995(2011)
DOI:
Determination of 19 Pesticide Residues in Tea Using QuEChERS Extraction and High-performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry. [J]. 30(9):990-995(2011)DOI:
Determination of 19 Pesticide Residues in Tea Using QuEChERS Extraction and High-performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry
A multiresidue method was developed for the simutaneous determination of 19 pesticides in tea by LC-MS/MS. The ionisation mode used was positive mode with multiple reaction monitoring.The one precursor/two product ion transitions were used for each neonicotinoids. The procedure,based on QuEChERS prior to the determination by UPLC-MS/MS,was validated based on the SANCO European Guidelines with satisfactory spiked recovery (68%–105%) and measurement uncertainty (≤20%). The results showed that the calibration curves were linear in the range of 1-15 μg/L for 18 analytes and 5-75 μg/L for difulubenzuron.The limits of quantitation (LOQ) were 50 μg?kg-1 for difulubenzuron and 10 μg?kg-1 for the other 18 pesticides. The method was simple,rapid and accurate,and could meet the requirement of the maximum residue limits (MRLs) for pesticides in tea as recommended by the European Union.
Large-scale Analysis of Pesticides in Fruits and Vegetables by Liquid Chromatography- Electrospray Tandem Mass Spectrometry with QuEChERS as Cleanup Step
Screening of 166 Pesticide Residues in Tea Based on Ultra High Performance Liquid Chromatography-Quadrupole/Electrostatic Field Orbitrap High Resolution Mass Spectrometry
Determination of 37 Pesticide Residues in Tea by Gas Chromatography-Tandem Mass Spectrometry Combined with QuEChERS and Prepositive Internal Standard
Determination of 290 Pesticide Residues in Tea by High Performance Liquid Chromatography-Tandem Mass Spectrometry
Related Author
No data
Related Institution
爱博才思亚太应用支持中心
Tea Research Institute,Chinese Academy of Agriculture Sciences
College of Chemical Engineering,Zhejiang University of Technology
Hanzhong Food and Drug Supervision,Inspection and Testing Center,Shaanxi Tea Products Quality Supervision and Inspection Center
Chenggu Food and Drug Inspection and Testing Center