Determination of 24 Trace Level of Rare Earth and Metal Elements in Coastal and Estuarine Seawater by Polymer Complexation-Ultrafiltration Technique and Inductively Coupled Plasma Mass Spectrometry
|更新时间:
|
Determination of 24 Trace Level of Rare Earth and Metal Elements in Coastal and Estuarine Seawater by Polymer Complexation-Ultrafiltration Technique and Inductively Coupled Plasma Mass Spectrometry
Vol. 30, Issue 12, Pages: 1430-1435(2011)
作者机构:
1. 厦门大学近海海洋环境科学国家重点实验室
2. 厦门大学海洋与环境学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of 24 Trace Level of Rare Earth and Metal Elements in Coastal and Estuarine Seawater by Polymer Complexation-Ultrafiltration Technique and Inductively Coupled Plasma Mass Spectrometry. [J]. 30(12):1430-1435(2011)
DOI:
Determination of 24 Trace Level of Rare Earth and Metal Elements in Coastal and Estuarine Seawater by Polymer Complexation-Ultrafiltration Technique and Inductively Coupled Plasma Mass Spectrometry. [J]. 30(12):1430-1435(2011)DOI:
Determination of 24 Trace Level of Rare Earth and Metal Elements in Coastal and Estuarine Seawater by Polymer Complexation-Ultrafiltration Technique and Inductively Coupled Plasma Mass Spectrometry
A method of polyacrylic acid-complexation and ultrafiltration for matrix modification and inductively coupled plasma mass spectrometry(ICP-MS)was developed for the determination of 24 trace level of rare earth elements(REEs) and metal elements in coastal and estuarine seawater.REEs ions,Cu2+,Pb2+,Cd2+,Co2+,Ni2+ could reacted with polyacrylic acid(PAA) to form stable complexes when the pH value was above 7.5,which could be separated and enriched absolutely after trapped and eluted from the ultrafilter.Full quantitative data collection mode and internal standard calibration curve were used for the ICP-MS determination.Under the optimized conditions,the relative standard deviations(RSDs) were in the range of 1.7%-7.3%,and the spiked recoveries were between 73% and 96%.The limits of quantitation(LOQs,10σ) ranged from 0.23 ng/L to 13.9 ng/L.The method blank ranged from 0.09 ng/L to 8.38 ng/L.The developed method could be applied in the simultaneous determination of REEs and metal elements in coastal and estuarine seawater.
关键词
聚丙烯酸-金属螯合物超滤电感耦合等离子体质谱海水稀土及金属元素
Keywords
poly(acrylic acid)-metal complexultrafiltrationinductively coupled plasma mass spectrometryseawaterrare earth and metal elements
Determination of 18 Phycotoxins in Seawater,Suspended Particulate Matter and Sediment by Ultrahigh Performance Liquid Chromatography-Tandem Mass Spectrometry
Recent Advance in Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry in Environmental Analysis
Research on Tumor Marker Determination Methods Based on Inductively Coupled Plasma Mass Spectrometry
Simultaneous Determination of Ultra trace Level of As,Sb,Bi,Ge,Sn and Hg in Coastal and Estuarine Seawater by Chemical Vapor Generation and Inductively Coupled Plasma Mass Spectrometry
Determination of Nine Trace Elements in Plant Samples by Inductively Coupled Plasma Mass Spectrometry in Mixed Mode
Related Author
No data
Related Institution
Department of Transportation and Environment,Shenzhen Institute of Information Technology
State Key Laboratory of Marine Pollution(SKLMP),City University of Hong Kong,Hongkong
Key Laboratory of Detection Technology R&D on Food Safety,Food Inspection and Quarantine Technology Center of Shenzhen Customs