In this paper,Tenax-TA tubes were used for air sampling with a small volume air sampler,and a gas chromatography-mass spectrometer(GC-MS) equipped with thermal desorber was adopted to analyze 4 simulant warfare agents,including 1,2-dichloroethane,N,N-dimethylacetamide,trimethyl phosphate and dimethyl methylphosphonate.The results showed that good linearities for four simulant CWAs were obtained in the range of 1-100 ng/tube with correlation coefficients(r2) more than 0.99.The average spiked recoveries were in the range of 82%-112%.The limits of detection(LODs) ranged from 0.13 ng/tube to 0.26 ng/tube,and the relative standard deviations(RSDs) were less than 15%.
Determination of Deltamethrin in Air by Membrane Adsorption Combined with Ultrasound-assisted Dispersive Liquid-Liquid Microextraction and High Performance Liquid Chromatography
Analysis of Six Volatile Fatty Acids in Air Using Dynamic Solid-phase Microextration-Gas Chromatography