Determination of Silicate in Cyclotella Meneghiniana Kiits Solution Using Non suppressed Conductance Detection Ion Chromatography
|更新时间:2023-05-18
|
Determination of Silicate in Cyclotella Meneghiniana Kiits Solution Using Non suppressed Conductance Detection Ion Chromatography
Vol. 31, Issue 1, Pages: 66-70(2012)
作者机构:
农业部渔业装备与工程技术重点实验室中国水产科学研究院渔业机械仪器研究所
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Silicate in Cyclotella Meneghiniana Kiits Solution Using Non suppressed Conductance Detection Ion Chromatography. [J]. 31(1):66-70(2012)
DOI:
Determination of Silicate in Cyclotella Meneghiniana Kiits Solution Using Non suppressed Conductance Detection Ion Chromatography. [J]. 31(1):66-70(2012)DOI:
Determination of Silicate in Cyclotella Meneghiniana Kiits Solution Using Non suppressed Conductance Detection Ion Chromatography
A novel method was developed for the determination of SiO2-3 in Cyclotella meneghiniana Kiits solution by non-suppressed conductance detection ion chromatography.The chromatography was performed on a Dionex anion AS23(4 mm×250 mm) analytical column and AG23(4 mm×50 mm) guard column with a constant temperature conductance detector.The experimental conditions were optimized,and the optimal chromatographic conditions were using 4 mmol/L sodium carbonate as eluent with a eluent speed of 1.0 mL/min,injection sample volume of 100 μL.The calibration curve of silicate was linear in the range of 0-40 mg/L.The detection limit was 0.017 mg/L.The relative standard deviation(RSD,n=7) for standard solution was lower than 5%.The RSDs for peak area and peak height measurements were 10.9% and 4.8%,respectively.The proposed method was applied in the determination of silicate in Cyclotella meneghiniana Kiits solution in different growing periods,and the spiked recoveries were in the range of 102%-120%.With the advantages of simplicity,good sensitivity,low cost,the method was suitable for the determination of silicate in cyclotella meneghiniana kiits solution.
关键词
离子色谱法非抑制电导检测硅酸根硅藻
Keywords
ion chromatographynon-suppressed conductance detectionsilicatediatom
Simultaneous Determination of Nine Chelators in Detergents by Ion Chromatography
Application Status and Prospect of Ion Chromatography in Hydrogen Detection for Hydrogen Fuel Cell Vehicles
Simultaneous Determination of Seven Inorganic Anions on the Surface of Printed Circuit Board(PCB) by Ion Chromatography with Microwave Preconcentration
Determination of Ionic Liquid Anion of p-Toluenesulfonate by Ion Chromatography with Direct Conductivity Detection
Determination of Monosaccharide and Disaccharide in Soy Sauce by Ion Chromatography
Related Author
No data
Related Institution
Key Laboratory of Green Cleaning Technology & Detergent of Zhejiang Province
NICE Zhejiang Technology Co. Ltd.
SINOPEC Research Institute of Petroleum Processing