Determination of Acetaminophen,Caffeine and Chlorphenamine Maleate in Compound Paracetamol and Amantadine Hydrochloride Capsules by Sweeping-MEKC Method
|更新时间:
|
Determination of Acetaminophen,Caffeine and Chlorphenamine Maleate in Compound Paracetamol and Amantadine Hydrochloride Capsules by Sweeping-MEKC Method
Vol. 31, Issue 3, Pages: 284-289(2012)
作者机构:
广西工学院生物与化学工程系
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Acetaminophen,Caffeine and Chlorphenamine Maleate in Compound Paracetamol and Amantadine Hydrochloride Capsules by Sweeping-MEKC Method. [J]. 31(3):284-289(2012)
DOI:
Determination of Acetaminophen,Caffeine and Chlorphenamine Maleate in Compound Paracetamol and Amantadine Hydrochloride Capsules by Sweeping-MEKC Method. [J]. 31(3):284-289(2012)DOI:
Determination of Acetaminophen,Caffeine and Chlorphenamine Maleate in Compound Paracetamol and Amantadine Hydrochloride Capsules by Sweeping-MEKC Method
A sweeping-micellar electrokinetic chromatographic(sweeping-MEKC) method was used for the simultaneous separation and determination of chlorphenamine maleate,caffeine and acetaminophen in compound paracetamol and amantadine hydrochloride capsules.Effects of sodium dodecyl sulfate(SDS) concentration,separation voltage,injection time of sample,composition and concentration of background buffer on separation efficiency were optimized.An optimal separation of three compounds was obtained on an uncoated fused silica capillary column(50 cm×50 μm,effective length 35 cm) by using background buffer containing 80 mmol/L SDS,20 mmol/L NaH2PO4 and 15% acetonitrile at pH 2.2 with a constant temperature of 25 ℃.The detection wavelength was set at 210 nm,the separation voltage at-20 kV and the sample injection time for 60 s.The result indicated that the separation of three compounds was performed within 25 min with relative standard deviation(RSDs) of their peak areas less than 4%.The calibration curves showed good linearities in the ranges of 2.45-39.17 mg/L for chlorphenamine,1.61-25.76 mg/L for caffeine and 1.58-25.28 mg/L for acetaminophen,with detection limits(S/N=3) of 139,34,24 μg/L,respectively.The spiked recoveries for acetaminophen,caffeine and chlorphenamine maleate were 96%-101%,98%-102% and 96%-102%,respectively.
Simultaneous Separation and Determination of Three Active Ingredients in Paracetamol Caffeine Aspirin Powder by Micellar Electrokinetic Capillary Chromatography
Separation and Determination of Effective Compounds in Alkaloidal Samples by Capillary Zone Electrophoresis
Rapid Determination of Caffeine in Milk Tea by Pseudo Reversed Phase Liquid Chromatography
Determination of Caffeine Using an Electrochemical Sensor Based on the Electropolymerized Molecularly Imprinted Film on a Multi-walled Carbon Nanotube Modified Glassy Carbon Electrode
Rapid Determination of Five Artificial Sweeteners,Six Iodinated X-ray Contrast Agents and Caffeine in Different Water Samples by Solid Phase Extraction with Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry