An ion-pair chromatographic method was developed for the determination of zinc 4-hydroxybenzene sulphonate in cosmetics with different matrixes.Lotion and shampoo samples were ultrasonically extracted with 20% acetonitrile aqueous solution,cream and powder samples were ultrasonically extracted with 80% acetonitrile aqueous solution,and lipstick samples were ultrasonically extracted with tetrahydrofuran and 80% acetonitrile aqueous solution,and then the extracts were centrifuged and filtered.Using tetrabutylammonium hydroxide as an ion pair reagent,the retention behavior of zinc 4-hydroxybenzene sulphonate and the optimum chromatographic conditions were investigated.The optimal conditions were as follows:stationary phase:Kromasil C18(4.6 mm×250 mm,5 μm),mobile phase:A (5 mmol/L tetrabutylammonium hydroxide and 25 mmol/L sodium dihydrogen phosphate at pH 2.5)∶B (acetonitrile)=80 ∶ 20,flow rate:1.0 mL/min,column temperature:30 ℃,detection wavelength:230 nm.Under the optimal conditions,the quantitation limits of zinc 4-hydroxybenzene sulphonate were 24 mg/kg for lotion and shampoo,120 mg/kg for cream and lipstick,and 60 mg/kg for powder.The calibration curve of zinc 4-hydroxybenzene sulphonate was linear in the range of 0.5-50 mg/L with a correlation coefficient of 0.999 8.The average recoveries at three spiked levels were between 94% and 99%,with relative standard deviations of 0.57%-3.9%.The method was rapid,simple and accurate,and could be used for the determination of zinc 4-hydroxybenzene sulphonate in cosmetics.
Determination of 8 Prohibited Tidine Drugs in Cosmetics by Ultra High Performance Liquid Chromatography-Triple Quadrupole Mass Spectrometry
Determination of Seven Dimethylcyclosiloxanes in Cosmetics by Gas Chromatography-Tandem Mass Spectrometry
Determination of Perfluorinated and Polyfluoroalkyl Substances in Cosmetics by Ultra High Performance Liquid Chromatography- Tandem Mass Spectrometry
Determination of Fifteen N-nitrosamine Compounds in Cosmetics by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Related Author
No data
Related Institution
Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology,Guangdong Provincial Engineering Research Center for Quality and Safety of Traditional Chinese Medicine,Institute of Analysis,Guangdong Academy of Sciences(China National Analytical Center,),Guangzhou
Guangzhou Institute for Drug Control
Institute of Analysis,Guangdong Academy of Sciences(China National Analytical Center,Guangzhou),Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology,Guangdong Provincial Engineering Research Center for Quality and Safety of Traditional Chinese Medicine
Guangdong Institute for Drug Control,National Medical Products Administration Key Laboratory for Safety Risk Assessment of Cosmetics
Guangzhou Quality Supervision and Testing Institute,National Quality Supervision and Testing Center for Cosmetics(),Guangzhou