Analysis of Chloramphenicol,Sulfonamides,Fluoroquinolones,Tetracyclines and Macrolides in Sewage Sludge by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Analysis of Chloramphenicol,Sulfonamides,Fluoroquinolones,Tetracyclines and Macrolides in Sewage Sludge by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 32, Issue 2, Pages: 179-185(2013)
作者机构:
1. 北京市朝阳区疾病预防控制中心
2. 北京市疾病预防控制中心
3. 食物中毒诊断溯源技术北京市重点实验室
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Analysis of Chloramphenicol,Sulfonamides,Fluoroquinolones,Tetracyclines and Macrolides in Sewage Sludge by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 32(2):179-185(2013)
DOI:
Analysis of Chloramphenicol,Sulfonamides,Fluoroquinolones,Tetracyclines and Macrolides in Sewage Sludge by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 32(2):179-185(2013)DOI:
Analysis of Chloramphenicol,Sulfonamides,Fluoroquinolones,Tetracyclines and Macrolides in Sewage Sludge by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
A comprehensive method was developed for the simultaneous analysis of 50 antibiotic drugs,including chloramphenicol,sulfonamides,fluoroquinolones,tetracyclines and macrolides in sewage sludge by ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The sludge samples were ultrasonically extracted with acetonitrile-water solution and then centrifugated.The supernatant were concentrated with an Oasis HLB solid-phase extraction(SPE) cartridge and purified with an amino SPE cartridge.The separation of 50 target drugs was performed on an ACQUITY UPLC BEH C18 column using a mobile phase of 0.1% formic acid-methanol(ESI+) or acetonitrile-water(ESI-)by gradient elution.A multiple reaction monitoring(MRM)was employed in mass spectrometry acquisition.The matrix matched external standard calibration was used for quantitation.Good linearities of the analytes were achieved over the concentration of 0.50-400 μg/L,with correlation coefficients above 0.99.The method quantitation limits(MQL)for target compounds were in the range of 0.10-5.00 μg/kg.Average recoveries of 50 analytes at three spiked levels ranged from 40% to 111% with relative standard deviations(RSDs)of 2.9%-27.1%.The developed method was applied in the analysis of target drugs in both activated and excess sludge samples from sewage treatment plants in Beijing,while 14 target compounds,namely sulfadiazine, sulfapyridine,sulfamethoxazole,pipemdilic acid,ofloxacin,enoxacin,pefloxacin,norfloxacin,ciprofloxacin,enrofloxacin,lomefloxacin,sparfloxacin,oxytetracycline and azithromycin,were detected in the concentration range of 1.2-442.5 μg/kg.The method was rapid,sensitive and reliable,and was suitable for the simultaneous determination of 50 antibiotics in sludge sample.
Study on the Method for the Identification of Sulfanilamide,Quinolone and Tetracycline in Urine by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Sulfonamides and Tetracyclines Antibiotics in Surface Sediments by Reversed Phase High Performance Liquid Chromatography
Aptamer Electrochemiluminescence Sensor for Sensitive Detection of Chloramphenicol
Preparation and Application of a Chloramphenicol Electrochemical Sensor Based on Molecularly Imprinted Polymer
Related Author
No data
Related Institution
Institute of Nutrition and Health,Chinese Center for Disease Control and Prevention
Beijing Center for Disease Control and Prevention,Beijing Center for Preventive Medicine Research