Determination of Sulfonylurea Herbicides in Environmental Water Using Solid Phase Extraction Disk Followed by High Performance Liquid Chromatography
|更新时间:
|
Determination of Sulfonylurea Herbicides in Environmental Water Using Solid Phase Extraction Disk Followed by High Performance Liquid Chromatography
Vol. 32, Issue 11, Pages: 1328-1332(2013)
作者机构:
1. 青岛理工大学环境与市政工程学院
2. 青岛市环境监测中心站
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Sulfonylurea Herbicides in Environmental Water Using Solid Phase Extraction Disk Followed by High Performance Liquid Chromatography. [J]. 32(11):1328-1332(2013)
DOI:
Determination of Sulfonylurea Herbicides in Environmental Water Using Solid Phase Extraction Disk Followed by High Performance Liquid Chromatography. [J]. 32(11):1328-1332(2013)DOI:
Determination of Sulfonylurea Herbicides in Environmental Water Using Solid Phase Extraction Disk Followed by High Performance Liquid Chromatography
A rapid analytical method based on C18 solid phase extraction disk followed by high performance liquid chromatography(HPLC) for the determination of six trace sulfonylurea herbicides,including tribenuron,metsulfuron-methyl,chlorsulfuron,bensulfuron-methyl,ethametsulfuron,chlorimuron-ethyl in water was developed.Chromatographic conditions were optimized,and the factors that influence the extraction,including type and volume of desorption solvent,pH value of sample and amount of salt addition were investigated.Experimental results showed that,the extraction efficiencies for 6 sulfonylurea herbicides in water were the highest by C18 SPE disk adsorption when the water samples were adjusted to pH 3.0,and the target compounds adsorped on C18 were eluted with 10 mL of methanol.Under the optimal conditions,good linear relationships(r2≥0.999 0) were obtained between peak areas and concentrations of 6 sulfonylurea herbicides in the ranges of 0.10-20.0 μg/L for tribenuron and 0.05-20 μg/L for the rest of the target compounds.The detection limits were in the range of 0.019-0.037 μg/L.The recoveries of 6 sulfonylurea herbicides in spiked water sample and seawater sample were in the ranges of 92.6%-105.7% and 89.8%-108.7%,with relative standard deviations (RSDs) of 0.7%-7.1% and 0.5%-4.0%,respectively.The method was simple,rapid,accurate and sensitive,and could provide a new option for the determination of sulfonylurea herbicides in environmental water.
Determination of 18 Phycotoxins in Seawater,Suspended Particulate Matter and Sediment by Ultrahigh Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of 31 Sulfonylurea Herbicide Residues in Soil by QuEChERS/Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Corrosive Sulfide Dibenzyl Disulfide in Transformer Oil by High Performance Liquid Chromatography with Liquid-Liquid Microextraction
Rapid Determination of 16 Local Anesthetic Components in Adult Products by High Performance Liquid Chromatography
Simultaneous Determination of 9 Sulfonylurea Herbicides in Corn Using Solid phase Extraction and Ultra Performance Liquid Chromatography with Electrospray Ionization Tandem Mass Spectrometry
Related Author
No data
Related Institution
Department of Transportation and Environment,Shenzhen Institute of Information Technology
State Key Laboratory of Marine Pollution(SKLMP),City University of Hong Kong,Hongkong
Key Laboratory of Detection Technology R&D on Food Safety,Food Inspection and Quarantine Technology Center of Shenzhen Customs