Determination of Vitamin B12 in Beverages by High Performance Liquid Chromatography Combined with On-line Clean-up/Solid-phase Extraction
|更新时间:2023-05-18
|
Determination of Vitamin B12 in Beverages by High Performance Liquid Chromatography Combined with On-line Clean-up/Solid-phase Extraction
Vol. 33, Issue 1, Pages: 39-44(2014)
作者机构:
1. 复旦大学环境科学与工程系
2. 赛默飞世尔科技中国有限公司
3. 山东省邹城市食品质量检验中心
4. 复旦大学化学系
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Vitamin B12 in Beverages by High Performance Liquid Chromatography Combined with On-line Clean-up/Solid-phase Extraction. [J]. 33(1):39-44(2014)
DOI:
Determination of Vitamin B12 in Beverages by High Performance Liquid Chromatography Combined with On-line Clean-up/Solid-phase Extraction. [J]. 33(1):39-44(2014)DOI:
Determination of Vitamin B12 in Beverages by High Performance Liquid Chromatography Combined with On-line Clean-up/Solid-phase Extraction
A high performance liquid chromatographic(HPLC)method combined with on-line clean-up and solid-phase extraction(SPE) was developed for the fast and effective determination of trace amount of vitamin B12(VB12) in beverages.A small change in the flow scheme of the traditional on-line SPE system reverses the flush direction on the SPE column,and creates an online SPE system with dual function(trapping the analytes and partially separating it from interferences prior to the analytical column) that eliminates interferences much more efficiently.The trapping of VB12 was completed by injecting 2.5 mL beverage sample into the SPE column(Thermo Scientific Acclaim PA Ⅱ,3 μm,3.0 mm×33 mm),using phosphate buffer-acetonitrile as mobile phase,and then the VB12 was partially separated on the SPE column by changing mobile phase gradient.Therefore,only those interferences co-eluting with VB12 entered the analytical column,and more interferences were removed.The volume of VB12 cut from the SPE column was separated on the analytical column(Thermo Scientific Acclaim PA Ⅱ,3 μm,3.0 mm×150 mm) using phosphate buffer-acetonitrile as mobile phase,and detected with UV detector at 361 nm.The complete analysis only took 20 min.The relative standard deviation(RSD) of VB12 was 0.027% for retention time,and 2.2% for peak area.Good linearity was obtained in the range of 0.1-5.0 μg/L with correlation coefficient of 0.999 9.The spiked recoveries for 4 beverage samples were in the range of 91%-109%,and the limit of detection for this method was 0.046 μg/L.Compared with the direct large-volume injection and the traditional on-line SPE system,this method was better expression in easy manipulation and effective clean-up.
关键词
在线固相萃取在线净化双梯度高效液相色谱系统阀切换饮料维生素B12
Keywords
on-line solid-phase extraction(SPE)on-line clean-updual-gradient high performance liquid chromatography(HPLC)valve-switchingbeveragevitamin B12
Determination of New Red in Beverages and Prepared Wines by HPLC-MS/MS with Solid Phase Extraction Based on Metal Organic Frameworks UiO-66-NH2
Rapid Analysis of Saccharin Sodium in Beverage and Fruit Based on Two dimensional Thin Layer Chromatography Coupled with Surface Enhanced Raman Scattering
Determination of Phenylalanine in Beverage by Using the Cu(Ⅱ)catalyzed Oscillating Chemical Reaction
Determination of Vitamin B12 Content in Milk Powder by Immunoaffinity Column Purification-HPLC Method
Preparation of a Gold Nanoparticles-Reduced Graphene Oxide Modified Glucose Oxidase Biosensor and Its Amperometric Determination of Glucose in Beverages
Related Author
No data
Related Institution
College of Life Science and Food Engineering, Hebei University of Engineering
College of Materials Science and Engineering,Hebei University of Engineering