Determination of Tyrosine Isomers in Irradiated Protein-containing Functional Food by Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Determination of Tyrosine Isomers in Irradiated Protein-containing Functional Food by Liquid Chromatography-Tandem Mass Spectrometry
Vol. 33, Issue 8, Pages: 946-950(2014)
作者机构:
1. 上海海洋大学食品学院
2. 上海出入境检验检疫局
3. 中国检验检疫科学研究院
4. 重庆出入境检验检疫局
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Tyrosine Isomers in Irradiated Protein-containing Functional Food by Liquid Chromatography-Tandem Mass Spectrometry. [J]. 33(8):946-950(2014)
DOI:
Determination of Tyrosine Isomers in Irradiated Protein-containing Functional Food by Liquid Chromatography-Tandem Mass Spectrometry. [J]. 33(8):946-950(2014)DOI:
Determination of Tyrosine Isomers in Irradiated Protein-containing Functional Food by Liquid Chromatography-Tandem Mass Spectrometry
A liquid chromatography-tandem mass spectrometric(LC-MS/MS) method was developed for the determination of tyrosine isomers(o-tyrosine and m-tyrosine) in protein-containing functional food.The sample was dissolved with 6 mol/L hydrochloric acid,staying overnight under 110 ℃ acid solution after full of nitrogen,then evaporated with a stream of nitrogen to near dryness and redissolved with water.The LC separation was performed on a Phenomenex Kinetex PFP column with 5 mmol/L ammonium acetate solution and methanol as mobile phases by gradient elution.The tyrosine isomers were determined by MS/MS in negative electrospray ionization(ESI) mode,and quantified by the matrix-matched(MRM) external standard method.Good separations were obtained between the tyrosine isomers and other impurity peaks .In 0.005-1.0 mg/L concentration range,the peak areas of tyrosine isomers against concentration showed good linear relationships with correlation coefficient(r2)more than 0.999.The average recoveries of tyrosine isomers in protein-containing function food at three spiked concentration levels ranged from 81.8% to 98.2%,with relative standard deviations(RSDs,n=6) less than 8.0%.The limit of quantitation(LOQs) were 5.0 μg/kg and 8.0 μg/kg,and the limits of detection(LODs) were 1.5 μg/kg and 2.4 μg/kg,respectively.This method was applied in real samples,and the result indicated that the radiation dose could be quantitatively evaluated by the linear correlation with coefficients of determination(r2) more than 0.98 in individual irradiated protein containing function food samples.The method could be applied in qualitative identification of tyrosine isomers in protein-containing functional food.
关键词
蛋白类功能食品邻酪氨酸间酪氨酸液相色谱-串联质谱
Keywords
protein-containing functional foodo-tyrosinem-tyrosineliquid chromatography-tandem mass spectrometry
Simultaneous Determination of 7 Triazole Alcohol Fungicides in Vegetables by Liquid Chromatography-Tandem Mass Spectrometry
Determination of Chloramine T in Cosmetics by Ultrasound assisted Hydrolyzation-LC and Validation by LC-MS/MS
Determination of Fumonisins in Cereals Using Liquid Chromatography-Tandem Mass Spectrometry
Quantitation of Clonazepam and Its Major Metabolite 7-Aminoclonazepam in Blood by Automated Solid Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry
Determination of Glufosinate Residue in Vegetables and Fruits by Liquid Chromatography-Tandem Mass Spectrometry with Purification of Solid Phase Extraction