Determination of Bovine Lactoferrin in Milk by Cation Exchange Chromatography and Dynamic Coating Capillary Electrophoresis
|更新时间:
|
Determination of Bovine Lactoferrin in Milk by Cation Exchange Chromatography and Dynamic Coating Capillary Electrophoresis
Vol. 33, Issue 3, Pages: 339-343(2014)
作者机构:
1. 深圳市福田区疾病预防与控制中心
2. 武汉大学化学与分子科学学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Bovine Lactoferrin in Milk by Cation Exchange Chromatography and Dynamic Coating Capillary Electrophoresis. [J]. 33(3):339-343(2014)
DOI:
Determination of Bovine Lactoferrin in Milk by Cation Exchange Chromatography and Dynamic Coating Capillary Electrophoresis. [J]. 33(3):339-343(2014)DOI:
Determination of Bovine Lactoferrin in Milk by Cation Exchange Chromatography and Dynamic Coating Capillary Electrophoresis
A dynamic coating capillary electrophoresis method with cation exchange chromatography was developed for the determination of bovine lactoferrin(bLF) in milk.The bLF was isolated from milk by using purolite C115-E cation exchange resin,and then quantitatively analyzed in the capillary coated by quaternized celluloses(QC).Effects of QC concentrations and pH values of the running buffer on the separation of bLF by capillary electrophoresis were investigated.It was shown that the use of QC coating in CE could drastically reduce the adsorption of bLF on the inner surface of fused silica capillary.QC can not only cover the silanol groups on the capillary inner surface,but also repel the basic proteins electrostatically to prevent bLF protein adsorption.After the optimization of analytical conditions,calibration with bLF protein was carried out and linear regression data were presented.Furthermore,the influences of extraction conditions such as incubation time on the extraction efficiencies of bLF were also investigated.The recoveries of bLF in milk at three spiked levels ranged from 87% to 112% with relative standard deviations(RSDs) of 4.4%-12.1%.This method had the advantages of rapidness,high efficiency,low sample and reagent consumption,and was suitable for the determination of bLF in milk.
Determination of Fluoroquinolones in Environmental Water Samples by Capillary Electrophoresis with Dispersive Liquid-Liquid Microextraction Based on Ultrasonic-assisted in-situ Formation and Solidification of Floating Deep Eutectic Solvent
Rapid and Sensitive Determination of Available Phosphorus in Soil by Capillary Electrophoresis with On-line Preconcentration and Contactless Conductivity Detection
Structural Elucidation of N-Glycans in IgG and Human Serum Glycoprotein Through the Combination of Offline Two-dimensional Chromatography and Exoglycosidase Sequencing
Simultaneous Separation and Determination of Seven Preservatives in Cosmetics by High Performance Capillary Electrophoresis
Determination of Buddleoside by Capillary Electrophoresis
Related Author
No data
Related Institution
School of Environmental and Pharmaceutical Engineering,Taizhou Institute of Science and Technology,Nanjing University of Science and Technology
Jiangsu Key Laboratory of Environmental Science and Engineering
School of Environmental Science and Engineering,Suzhou University of Science and Technology