Simultaneous Determination of 16 Kinds of Oil-soluble Synthetic Dyes in Feeds by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Gel Permeation Chromatography Clean-up Procedure
|更新时间:
|
Simultaneous Determination of 16 Kinds of Oil-soluble Synthetic Dyes in Feeds by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Gel Permeation Chromatography Clean-up Procedure
Vol. 33, Issue 11, Pages: 1262-1267(2014)
作者机构:
1. 河南省兽药监察所
2. 中国农业科学院饲料所
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of 16 Kinds of Oil-soluble Synthetic Dyes in Feeds by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Gel Permeation Chromatography Clean-up Procedure. [J]. 33(11):1262-1267(2014)
DOI:
Simultaneous Determination of 16 Kinds of Oil-soluble Synthetic Dyes in Feeds by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Gel Permeation Chromatography Clean-up Procedure. [J]. 33(11):1262-1267(2014)DOI:
Simultaneous Determination of 16 Kinds of Oil-soluble Synthetic Dyes in Feeds by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Gel Permeation Chromatography Clean-up Procedure
A method based on ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)with gel permeation chromatography was developed for the quantitative analysis of 16 kinds of oil-soluble synthetic dyes in feeds.The conditions of sample preparation and analysis were optimized in this thesis.The dyes were firstly extracted with 20 mL of ethyl acetate-cyclohexane(1∶1),and 5 mL of the extract was injected into the gel permeation chromatography(GPC)cleanup system.The elution was performed with a mixture of ethyl acetate-cyclohexane(1∶1) at a flow rate of 5 mL/min.The elution fraction in 15.8-48.3 min was collected.A UPLC separation was carried on a BEH C18 column(1.0 mm×100 mm,1.7 μm)by gradient elution using methanol -0.1% formic acid as mobile phase at a flow rate of 0.3 mL/min16 kinds of dyes were detected under positive electrospray ionization(ESI).The method was quantified by the external standard method and the linear ranges for 16 kinds of dyes were in the range of 2-100 μg/L with correlation coefficients greater than 0.99.The average recoveries for 16 kinds of dyes in feeds ranged from 66.4% to 108.5% at three different levels.The limits of detection were 25 μg/kg and the limits of quantitation were 50 μg/kg.The results indicated that the method developed was highly sensitive and selective in determination of 16 kinds of oil-soluble synthetic dyes in feeds.
关键词
超高效液相色谱-串联三重四极杆质谱脂溶性染料饲料凝胶色谱
Keywords
ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)oil-soluble synthetic dyesfeedsgel permeation chromatography(GPC)
Determination of Benzodiazepines in Animal Feeds by UPLC-ESI MS/MS
Rapid Screening of 36 Forbidden Drugs in Feeds by Using Liquid Chromatography-Quadrupole/Time-of-flight Mass Spectrometry
Simultaneous Determination of Twelve Sweeteners in Feeds by High Performance Liquid Chromatography / Evaporative Light Scattering Detection
Rapid Determination of Three Fumonisins in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry with Solid Phase Extraction
Determination of Aflatoxins in Aquatic Feeds Samples by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Multi component Immunoaffinity Column Purification