Determination of Estrogens in Sewage Sludge by Matrix Dispersion Solid-phase Extraction with High Performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:2023-05-18
|
Determination of Estrogens in Sewage Sludge by Matrix Dispersion Solid-phase Extraction with High Performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 34, Issue 1, Pages: 56-61(2015)
作者机构:
1. 苏州科技学院环境科学与工程学院
2. 苏州科技学院江苏省环境科学与工程重点实验室
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Estrogens in Sewage Sludge by Matrix Dispersion Solid-phase Extraction with High Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 34(1):56-61(2015)
DOI:
Determination of Estrogens in Sewage Sludge by Matrix Dispersion Solid-phase Extraction with High Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 34(1):56-61(2015)DOI:
Determination of Estrogens in Sewage Sludge by Matrix Dispersion Solid-phase Extraction with High Performance Liquid Chromatography-Tandem Mass Spectrometry
A matrix solid-phase dispersion(MSPD) with high performance liquid chromatography tandem mass spectrometric(HPLC-MS/MS) method was established for the simultaneous determination of six estrogens(estriol,estradiol,17α-ethinylestradiol,estrone,diethylstilbestrol and bisphenol A) in sewage sludge.The 0.3 g sewage sludge sample was mixed with 1.5 g Florisil for matrix solid phase dispersion by using the new grinding method,then the mixed sample was transferred to a column and eluted with 6 mL methanol.The eluent was purified by dispersive solid phase extraction(DSPE) using HC-C18 as cleaning agent,and then concentrated to 0.6 mL by nitrogen.The six estrogens were separated upon a Syncronis C18 column using acetonitrile-water as mobile phase by gradient elution,and detected by MS under selected reaction monitoring(SRM) mode.The external standard method was used for quantitation analysis.The results indicated that six target estrogens can achieve the good linearities in the range of 1-50 μg?kg-1,with correlation coefficients higher than 0.992.The limits of detection(LODs) for the target compounds ranged from 0.12 μg?kg-1 to 0.25 μg?kg-1.Average recoveries of 6 analytes at three spiked levels ranged from 81.4% to 107.3% with relative standard deviations(RSDs) of 1.8%-9.7%.The developed method was applied in the analysis of 6 estrogens in sewage sludge samples from two sewage treatment plants in Suzhou,of which 5 target compounds except diethylstilbestrol were detected with concentration of 1.08-24.3 μg?kg-1.The method was rapid,sensitive and reliable,and was suitable for the simultaneous determination of trace estrogen in sewage sludge.
关键词
雌激素污泥基质固相分散萃取高效液相色谱-串联质谱(HPLC-MS/MS)
Keywords
estrogenssewage sludgematrix solid-phase dispersion extraction(MSPD)high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)
Determination of Five Halogenated Methyl Sulfonic Acids in Sludge from Municipal Sewage Treatment Plant by HPLC-MS/MS
Simultaneous Determination of 30 Hormones and Chloramphenicols Residues in Fish Using QuEChERS Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry
Simultaneous Determination of Total Specific Migration Limit of 9 Types of Ultraviolet Absorbers in Food Simulants by High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Kasugamycin Residues in Cucumber and Soil by Solid Phase Extraction/High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Paraquat and Diquat Residues in Water by High Performance Liquid Chromatography-Tandem Mass Spectrometry with Solid Phase Extraction