Simultaneous Determination of Trace Benzotriazoles and Benzothiazoles in Water by Large-volume Injection/Gas Chromatography-Mass Spectrometry
|更新时间:2023-05-18
|
Simultaneous Determination of Trace Benzotriazoles and Benzothiazoles in Water by Large-volume Injection/Gas Chromatography-Mass Spectrometry
Vol. 34, Issue 3, Pages: 341-345(2015)
作者机构:
1. 中国科学院南海海洋研究所
2. 中国科学院大学
3. 环境保护部南京环境科学研究所
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of Trace Benzotriazoles and Benzothiazoles in Water by Large-volume Injection/Gas Chromatography-Mass Spectrometry. [J]. 34(3):341-345(2015)
DOI:
Simultaneous Determination of Trace Benzotriazoles and Benzothiazoles in Water by Large-volume Injection/Gas Chromatography-Mass Spectrometry. [J]. 34(3):341-345(2015)DOI:
Simultaneous Determination of Trace Benzotriazoles and Benzothiazoles in Water by Large-volume Injection/Gas Chromatography-Mass Spectrometry
A rapid and reliable analytical method,based on large-volume injection and gas chromatography-mass spectrometry(PTV/GC-MS) was developed for the determination of 12 benzotriazoles and benzothiazoles in aquatic matrixes.1.0 L water samples were acidified to pH 3.0 using 3 mol/L HCl.The samples were then passed through an Oasis HLB cartridge.The analytes were eluted with 6 mL methanol-acetonitrile(1∶1).The solution was evaporated to dryness under a gentle stream of nitrogen,and redissolved in acetone,internal standard and silylation reagent.The sealed vials were incubated at 38 ℃ for 1 h before instrument analysis.The separation of target compounds was achieved in a DB-5MS fused-silica capillary column.The analytes were detected in selected ion monitoring(SIM) that operated in electron impact(EI) mode.The calibration curves of 12 target compounds were linear in the range of 0.1-100 ng/L with correlation coefficients not less than 0.992.Spiked recoveries of the target analytes were in the ranges of 46%-116% for tap water,and 43%-117% for river water,with RSDs of 1.0%-16% and 1.0%-15%,respectively.The method detection limits for tap water and river water were in the ranges of 0.050-1.3 ng/L and 0.057-1.8 ng/L,respectively.The method was simple and sensitive,and was successfully employed in the detection of corrosion inhibitors in river water collected from the city section of the Pearl River.
关键词
缓蚀剂固相萃取硅烷化气相色谱-质谱联用河水
Keywords
corrosion inhibitorsolid phase extractionsilylationgas chromatography-mass spectrometry(GC-MS)river water
Determination of Five Organophosphate Ester Metabolites in Surface Water Samples by LC-MS/MS
Determination of Thiencarbazone-methyl and Its Metabolites in Different Environmental Matrixes by Liquid Chromatography- Tandem Mass Spectrometry
Simultaneous Determination of 12 Organophosphate Esters in Soil by Solid Phase Extraction/High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of 53 Semi-volatile Organic Compounds in Solid Waste by Gas Chromatography-Mass Spectrometry with Microwave Extraction and Solid Phase Extraction Column Purification
Determination of New Red in Beverages and Prepared Wines by HPLC-MS/MS with Solid Phase Extraction Based on Metal Organic Frameworks UiO-66-NH2
Related Author
No data
Related Institution
青岛理工大学环境与市政工程学院
中国环境科学研究院环境基准与风险评估国家重点实验室
中国科学院生态环境研究中心环境化学与生态毒理学国家重点实验室
Key Laboratory of Pesticide Environmental Assessment and Pollution Control,Ministry of Environmental Protection,Nanjing Institute of Environmental Sciences,Ministry of Ecology and Environment of the People’s Republic of China
College of Carbon Neutral Modern Industry,College of Environmental and Resource Science,Fujian Normal University