Automated Determination of Three Kinds of Aromatic Amines by On-line Hollow Fiber Liquid-phase Microextraction/High Performance Liquid Chromatography
|更新时间:
|
Automated Determination of Three Kinds of Aromatic Amines by On-line Hollow Fiber Liquid-phase Microextraction/High Performance Liquid Chromatography
Vol. 34, Issue 10, Pages: 1142-1146(2015)
作者机构:
1. 上海师范大学环境系
2. 浙江清华长三角研究院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Automated Determination of Three Kinds of Aromatic Amines by On-line Hollow Fiber Liquid-phase Microextraction/High Performance Liquid Chromatography. [J]. 34(10):1142-1146(2015)
DOI:
Automated Determination of Three Kinds of Aromatic Amines by On-line Hollow Fiber Liquid-phase Microextraction/High Performance Liquid Chromatography. [J]. 34(10):1142-1146(2015)DOI:
Automated Determination of Three Kinds of Aromatic Amines by On-line Hollow Fiber Liquid-phase Microextraction/High Performance Liquid Chromatography
A new method for the automated determination of three kinds of trace aromatic amines(o-toluidine,3,3′-dimethylbenzidine,β-naphthyl amine) was developed using on-line hollow fiber liquid phase microextraction/high performance liquid chromatography. An online detection device was built by connecting the hollow fiber liquid-phase microextraction device and high performance liquid chromatography with sequential injection device. The influences of extraction parameters including extracting solvent,donor phase,acceptor phase,salt effect,stirring rate and extraction time were investigated with this online device.The optimum experimental conditions were as follows:extraction reagent:1-octanol,donor phase:0.1 mol?L-1 NaOH-300 mg?L-1 NaCl,acceptor phase:0.1 mol?L-1 HCl, stirring rate:400 revolution per minute(r/min),extraction time:40 min.Under the optimum conditions,the qualitative and quantitative analyses of three kinds of trace aromatic amines were preformed by HPLC.The proposed method provided enrichment folds of 48-96.Good linearities were obtained in the range of 0.01-0.25 mg?L-1 with correlation coefficients not less than 0.998 4.The detection limits(S/N=3) were in the range of 0.3-2.2 μg?L-1 ,and RSDs(n=10) were 3.1%-4.0%.The spiked recoveries of aromatic amines in printing and dyeing wastewater ranged from 98.0% to 102.0%.With the advantage of simplicity,rapidness,less consumption of extracting solvent,high enrichment factor,and great precision for detection,this method is effective for fast and accurate analysis of trace aromatic amines.
Homogeneous Synthesis of Novel Amphiphilic C22 Stationary Phases with Multiple Selectivity
Advances in the Analysis of Organic Contaminants in Sediments and Particulate Matters by Liquid Chromatography-High Resolution Mass Spectrometry
Research on Status of Column Fillers for Gel Permeation Chromatography
Determination of Chloramine T in Cosmetics by Ultrasound assisted Hydrolyzation-LC and Validation by LC-MS/MS
Rapid Detection of Trace Amounts of Nitroimidazoles and Their Metabolites in Honey Using Liquid Chromatography Coupled with Quadrupole/Linear Ion Trap Mass Spectrometry
Related Author
No data
Related Institution
CAS Key Laboratory of Analytical Chemistry for Living Biosystems,Institute of Chemistry,Chinese Academy of Sciences
International Cooperation Joint Laboratory for Intelligent Preparation of High-end Functional Mineral Salt Materials,National & Local Joint Engineering Research Center for Mineral Salt Deep Utilization,Huaiyin Institute of Technology,Huai’an
Qingdao Customs Technology Center
Key Laboratory of Marine Environment and Ecology, Ministry of Education, Ocean University of China