Determination of Azodicarbonamide in Flour Products by High Performance Liquid Chromatography-Fluorescence Detector Coupled with Precolumn Derivatization
|更新时间:
|
Determination of Azodicarbonamide in Flour Products by High Performance Liquid Chromatography-Fluorescence Detector Coupled with Precolumn Derivatization
Vol. 34, Issue 12, Pages: 1430-1433(2015)
作者机构:
1. 长沙市食品质量安全监督检测中心
2. 湖南澄源检测有限公司
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Azodicarbonamide in Flour Products by High Performance Liquid Chromatography-Fluorescence Detector Coupled with Precolumn Derivatization. [J]. 34(12):1430-1433(2015)
DOI:
Determination of Azodicarbonamide in Flour Products by High Performance Liquid Chromatography-Fluorescence Detector Coupled with Precolumn Derivatization. [J]. 34(12):1430-1433(2015)DOI:
Determination of Azodicarbonamide in Flour Products by High Performance Liquid Chromatography-Fluorescence Detector Coupled with Precolumn Derivatization
A method was developed for the determination of azodicarbonamide(ADA) in flour products using dansyl chloride(DNS-Cl) precolumn derivatization combined with high performance liquid chromatography-fluorescence detector.ADA in flour products was hydrolyzed by wet heat processing and formed semicarbazide(SEM) finally.SEM was derivatized with DNS-Cl.The derivatization product was separated on an Aglient TC C18 column(250 mm× 4.6 mm,5 μm) using acetonitrile-water(65∶35) as mobile phase at a flow rate of 1.0 mL/min.The oven temperature was set at 30 ℃,the excitation wavelength was 330 nm and the detection wavelength was 530 nm.Under the optimal conditions,the linear range for ADA was in the range of 0.1-50 mg/L with correlation coefficient(r) higher than 0.998.The limits of detection(LOD)and limits of quantitation(LOQ) for the method were 0.03 mg/L and 0.10 mg/L,respectively.The spiked recoveries of ADA at three levels of 0.1,0.3,1.0 mg/kg ranged from 78.4%to 96.6%with RSDs of 7.1%-9.4%.With advantages of simplicity,rapidness and sensitivivity,the method was successfully applied in the analysis of ADA in flour products.
Analysis of Monosaccharide Composition and Content in Mesona Chinensis Benth Polysaccharides by Precolumn Derivatization Ultra-high Performance Liquid Chromatography-Tandem Quadrupole Mass Spectrometry
Determination of Tranexamic Acid in Toothpaste by High Performance Liquid Chromatography
Determination of 18 Amino Acids in Gelatin from Bovine and Yak by High Performance Liquid Chromatography Coupled with Precolumn Derivatization
Determination of Imidazole in Cigarette Additives by High Performance Liquid Chromatography with Pre-column Derivatization