Evaluation of QuEChERS Method for the Analysis of 15 Triazole Pesticides Residues in Fruits by Online Gel Permeation Chromatography Gas Chromatography-Mass Spectrometry
|更新时间:
|
Evaluation of QuEChERS Method for the Analysis of 15 Triazole Pesticides Residues in Fruits by Online Gel Permeation Chromatography Gas Chromatography-Mass Spectrometry
Vol. 34, Issue 12, Pages: 1331-1338(2015)
作者机构:
1. 中国农业科学院果树研究所
2. 农业部果品质量安全风险评估实验室(兴城)
3. 农业部果品及苗木质量监督检验测试中心(兴城)
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Evaluation of QuEChERS Method for the Analysis of 15 Triazole Pesticides Residues in Fruits by Online Gel Permeation Chromatography Gas Chromatography-Mass Spectrometry. [J]. 34(12):1331-1338(2015)
DOI:
Evaluation of QuEChERS Method for the Analysis of 15 Triazole Pesticides Residues in Fruits by Online Gel Permeation Chromatography Gas Chromatography-Mass Spectrometry. [J]. 34(12):1331-1338(2015)DOI:
Evaluation of QuEChERS Method for the Analysis of 15 Triazole Pesticides Residues in Fruits by Online Gel Permeation Chromatography Gas Chromatography-Mass Spectrometry
A comparison was made among three versions of QuEChERS sample preparation methods for the extraction of 15 triazole pesticides in fruits.The three QuEChERS methods were the original method without buffer,the AOAC Official Method 2007.01 with acetate buffer,and the CEN 15662 Method with citrate buffer.The clean-up effects of primary secondary amine(PSA) sorbent and C18 sorbent on 15 triazole pesticides were studied.The addition method after extraction was used to evaluate the matrix effects of triazole pesticide in matrix of apple,pear,peach,grape,cherry,banana and orange during gel permeation chromatography coupled to gas chromatography-mass spectrometry(GPC/GC-MS) analysis.As a result,the QuEChERS method without buffer gave good recoveries for 15 triazole pesticides. The cleaning up effect of PSA plus C18 is superior to that of C18 or PSA sorbent.The matrix effects were intensive in the 7 kinds of fruits.In this article,15 triazole pesticides were extracted by the QuEChERS method without buffer,and analysed by using matrix-matched standard calibration as the external standard method with gas chromatography-mass spectrometry in selective ion monitoring(SIM) mode.Moreover,a large volume of sample was allowed to be injected using the program of GPC programmed temperature vaporizer of gas chromatography to improve the sensitivity of measurements.The recoveries of 15 residues in 7 matrixes at three spiked levels of 20,50,100μg/kg ranged from 85.7% to 120.1% with relative standard deviations of 0.2%-11.5%.The calibration curves were linear(r>0.998) in the range of 10-400μg/L for all the pesticides.The limits of detection(LOD) for the pesticides in fruits ranged from 0.9μg/kg to 9.5μg/kg.Based on these results,the analytical method was proved to be highly efficient,robust and sensitive,and was suitable for monitoring 15 triazole pesticides residues in fruits.
关键词
QuEChERS在线凝胶渗透色谱串联气相色谱-质谱三唑类农药残留基质效应水果
Keywords
QuEChERSonline gel permeation chromatography/gas chromatography-mass spectrometry(GPC/GC-MS)triazole pesticidesmatrix effectsfruits
Determination of 77 Pesticide Residues in Vegetables and Fruits by Liquid Chromatography-High Resolution Mass Spectrometry Coupled with QuEChERS and Cold Induced Liquid-Liquid Extraction
Determination of 31 Organophosphorous Pesticide Residues in Fruits by Gas Chromatography with QuEChERS Sample Preparation
Detection of Matrix Effects of 17 Carbamate Pesticides in 5 Vegetables by QuEChERS/LC-MS/MS Method
Residue Determination of Niclosamide-olamine in Twenty Two Kinds of Agricultural Products by UPLC-MS/MS
Simultaneous Determination of 16 Coumarins and Vanillins and Their Derivatives in Rice by QuEChERS-Isotope Internal Standard/Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
Related Author
No data
Related Institution
NHC Key Laboratory of Food Safety Risk Assessment, China National Center for Food Safety Risk Assessment