A method was developed for the simultaneous determination of hexoestrolum,diethylstilbestrol,dienestrol,estrone,17β-estradiol and estriol in feed by solid phase extraction and gas chromatography-mass spectrometry(GC-MS).After extracted with ethyl ether and cleaned up on an HLB phase extraction column,six kinds of estrogens were derived and quantified by GC-MS.The external standard calibration curves were used for the quantification.The results showed that the high linear ranges from 2.5 ng/mL to 250 ng/mL for hexoestrolum and from 5 ng/mL to 500 ng/mL for five other estrogens were obtained with correlation coefficients (r2) not less than 0.99.The limits of detection were in the range of 3-8 μg/kg and the average recoveries were 75.9%-96.3%.The results demonstrated that the developed method could be applied in the qualitative and quantitative determination of six kinds of estrogens in feed with low limit of detection and high accuracy.
关键词
气相色谱-质谱己烷雌酚己烯雌酚双烯雌酚雌酮雌二醇雌三醇饲料
Keywords
gas chromatography-mass spectrometry(GC-MS)hexoestrolumdiethylstilbestroldienestrolestrone17β estradiolestriolfeed
Simultaneous Determination of Eight Cathinones New Psychoactive Substances in Urine by Gas Chromatography-Mass Spectrometry
Analysis of Macrolide Antibiotics in Feeds by High Performance Liquid Chromatography-Tandem Mass Spectrometry Based on Solid Phase Extraction
Simultaneous Determination of 18 Chlorinated Hydrocarbon Organic Solvents in Dyeing and Finishing Auxiliaries by Gas Chromatography-Mass Spectrometry
Simultaneous Determination of Clenbuterol,Chloramphenicol and Diethylstilbestrol in Bovine Milk by Isotope Dilution Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Removal of Diethylstilbestrol in Environmental Water by Dispersive Solid-phase Extraction Using Graphene/Fe3O4 Magnetic Nanocomposite as Adsorbent