Simultaneous Determination of 53 Kinds of Glucocorticoids Illegally Added in Facial Mask Cosmetics by Solid-phase Extraction with Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Simultaneous Determination of 53 Kinds of Glucocorticoids Illegally Added in Facial Mask Cosmetics by Solid-phase Extraction with Liquid Chromatography-Tandem Mass Spectrometry
Vol. 35, Issue 2, Pages: 119-126(2016)
作者机构:
中国广州分析测试中心广东省化学危害应急检测技术重点实验室
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of 53 Kinds of Glucocorticoids Illegally Added in Facial Mask Cosmetics by Solid-phase Extraction with Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(2):119-126(2016)
DOI:
Simultaneous Determination of 53 Kinds of Glucocorticoids Illegally Added in Facial Mask Cosmetics by Solid-phase Extraction with Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(2):119-126(2016)DOI:
Simultaneous Determination of 53 Kinds of Glucocorticoids Illegally Added in Facial Mask Cosmetics by Solid-phase Extraction with Liquid Chromatography-Tandem Mass Spectrometry
A comprehensive analytical method was developed and validated for the simultaneous determination of 53 kinds of glucocorticoids in facial mask cosmetics using solid-phase extraction(SPE) coupled with liquid chromatography-tandem mass spectrometry(LC-MS/MS).Cosmetic sample was dispersed with water,and the analytes were extracted with methanol by vortex mixer.The extracts were cleaned up with a Cleanert PEP(60mg,3mL) solid phase extraction cartridge after diluted with water. Electrospray ionization mass spectrometry was performed in the positive mode using dynamic multiple reaction monitor(DMRM) mode for the qualitative and quantitative analyses of 53 kinds of analytes after separation on a column of Waters CORTECS C18+(100mm×2.1mm,2.7μm).The correlation coefficients for linear calibration curves were over 0.99 in the corresponding concentration range.The average recoveries of 53 drugs from spiked sample at three different concentration levels ranged from 66.8%to 106.3%, with relative standard deviation(RSDs)of 3.9%-13.2%.The limits of detection(LODs,S/N≥3) and quantitation(LOQs,S/N≥10) were 3μg/kg and 10μg/kg, respectively.The established method is simple,reliable,accurate and sensitive,and is suitable for the determination of glucocorticoids illegally added in cosmetics.
关键词
化妆品糖皮质激素固相萃取液相色谱-串联质谱法动态多反应监测非法添加
Keywords
cosmeticsglucocorticoidssolid-phase extraction(SPE)liquid chromatography-tandem mass spectrometry(LC-MS/MS)dynamic multiple reaction monitoring(DMRM)illegal addition
Determination of Benvitimod in Cream Cosmetics by QuEChERS/Gas Chromatography-Tandem Mass Spectrometry
Detection of 73 Glucocorticoids in Cosmetics by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Pass-through Column Purification
Determination of 8 Prohibited Tidine Drugs in Cosmetics by Ultra High Performance Liquid Chromatography-Triple Quadrupole Mass Spectrometry
Determination of Seven Dimethylcyclosiloxanes in Cosmetics by Gas Chromatography-Tandem Mass Spectrometry
Related Author
No data
Related Institution
Institute of Analysis,Guangdong Academy of Sciences(China National Analytical Center,Guangzhou),Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology,Guangdong Provincial Engineering Research Center for Quality and Safety of Traditional Chinese Medicine
湖北省药品监督检验研究院
湖北省药品质量检测与控制工程技术研究中心
Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology,Guangdong Provincial Engineering Research Center for Quality and Safety of Traditional Chinese Medicine,Institute of Analysis,Guangdong Academy of Sciences(China National Analytical Center,),Guangzhou