Determination of Three Quaternary Ammonium Compounds in Ice Creams by Solid Phase Extraction and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Determination of Three Quaternary Ammonium Compounds in Ice Creams by Solid Phase Extraction and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 35, Issue 5, Pages: 609-613(2016)
作者机构:
嘉应学院梅州师范分院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Three Quaternary Ammonium Compounds in Ice Creams by Solid Phase Extraction and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(5):609-613(2016)
DOI:
Determination of Three Quaternary Ammonium Compounds in Ice Creams by Solid Phase Extraction and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(5):609-613(2016)DOI:
Determination of Three Quaternary Ammonium Compounds in Ice Creams by Solid Phase Extraction and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
A new method was developed for the determination of three quaternary ammonium compounds(QACs) residues,including dodecyl dimethyl benzyl ammonium chloride(C12-BAC),hexadecyl dimethyl benzyl ammonium chloride(C16-BAC) and benzethonium chloride in ice creams using solid phase extraction(SPE) and ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The samples were melted and mixed,and then added into acetonitrile to extract target compounds and precipitate protein.The supernatant was purified with weak cationic exchange solid phase extraction cartridge(WCX) and concentrated in nitrogen stream.The separation of three quaternary ammonium compounds was performed on a Waters BEH HILIC column(50 mm×2.1 mm,1.7 μm) by isocratic elution using acetonitrile(containing 0.1% formic acid)-10 mmol/L ammonium acetate as mobile phase.The targets were analyzed under the multiple reaction monitoring(MRM)mode in positive electrospray ionization.The results showed that the calibration curves of three QACs were linear in the range of 0.5-20 μg/L with correlation coefficients greater than 0.999.The method quantitation limits(LOQs,S/N=10)of three analytes ranged from 3.0 μg/kg to 5.5 μg/kg.The average recoveries were in the range of 90.7%-102.2%,and the relative standard deviation(RSD,n=6) were 2.4%-6.4% at three spiked levels of standard.With the advantages of simplicity,accuracy,sensitivity and good reproducibility,the method could be used for the determination of QACs residues in ice creams. Key words:quaternary ammonium compounds;ice creams;ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS);solid phase extraction(SPE)
Effects of Three Kinds of Solid Phase Extraction Columns Purification Methods on Determination of 8 Antibiotics Residues in Dairy by High Performance Liquid Chromatography
Simultaneous Determination of Six Pyrazole Fungicides in Grape Wine by Liquid Chromatography-Tandem Mass Spectrometry
Identification of Four Active Constituents in Hair Growth Cosmetics by Ultra Performance Liquid Chromatography Coupled with Quadrupole Time-of-Flight Mass Spectrometry
Determination of Safrole and its Derivatives in Foodstuffs by Gas Chromatography-Mass Spectrometry
Determination of 15 Kinds of Phenoxyacid Herbicides in Tobacco by Gas Chromatography-Tandem Mass Spectrometry