Determination of Phenol in an Unknown Mixture Using Three-dimensional Fluorescence Coupled with Second-order Calibration Methods
|更新时间:
|
Determination of Phenol in an Unknown Mixture Using Three-dimensional Fluorescence Coupled with Second-order Calibration Methods
Vol. 35, Issue 6, Pages: 654-661(2016)
作者机构:
太原理工大学化学化工学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Phenol in an Unknown Mixture Using Three-dimensional Fluorescence Coupled with Second-order Calibration Methods. [J]. 35(6):654-661(2016)
DOI:
Determination of Phenol in an Unknown Mixture Using Three-dimensional Fluorescence Coupled with Second-order Calibration Methods. [J]. 35(6):654-661(2016)DOI:
Determination of Phenol in an Unknown Mixture Using Three-dimensional Fluorescence Coupled with Second-order Calibration Methods
A new approach was proposed for the determination of phenol in an unknown mixture by using three-dimension fluorescence coupled with second-order calibration methods based on rank annihilation factor analysis(RAFA),generalized rank annihilation factor analysis(GRAFA) and alternating trilinear decomposition(ATLD) algorithms,respectively.Fluorescence spectra were detected at consecutive time points in excitation range of 240-280 nm and emission range of 280-360 nm for each sample.Therefore,a three-way response data array was established and analyzed by second-order calibration method of trilinear decomposition.When the component number of sample was set to 2,the obtained average recoveries(AR) of phenol were 101.6%,115.6%,101.9%,and the root-mean-squared errors of prediction(RMSEP) for RAFA,GRAFA and ATLD were 0.33,1.18 and 0.15,respectively.When the component number of sample was set to 3,the obtained average recoveries of phenol were 134.2%,133.9%,107.1%,and the root-mean-squared errors of prediction for RAFA,GRAFA and ATLD were 1.61,1.80 and 0.51,respectively.The proposed method was applied in the determination of phenol in actual water samples with satisfactory results,and the associated verified experiments showed that ATLD is superior to RAFA and GRAFA.
Determination of 10 Kinds of Restricted Substances in Cosmetics by High Performance Liquid Chromatography with Photodiode Array Detector
Investigation on Thermal Decomposition Behaviors of Chlorogenic Acid at Different Atmospheres and Content Distribution of Phenol in Its Pyrolysis Products
A Discrimination Method on Fat Oxidation of Dairy Product Based on Three-dimensional Fluorescence Spectroscopy
Determination of Quercetin in Herbal Gynostemma Pentaphyllum by Using Excitation-Emission Matrix Fluorescence Coupled with Second-order Calibration Method
Electrogenerated Chemiluminescence Analysis of Phenol Using ZnO Modified Pencil Graphite Electrode