Determination of Furoic Acid in Transformer Oil by Using Reversed Phase Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography
|更新时间:
|
Determination of Furoic Acid in Transformer Oil by Using Reversed Phase Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography
Vol. 35, Issue 3, Pages: 311-316(2016)
作者机构:
中南民族大学化学与材料科学学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Furoic Acid in Transformer Oil by Using Reversed Phase Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography. [J]. 35(3):311-316(2016)
DOI:
Determination of Furoic Acid in Transformer Oil by Using Reversed Phase Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography. [J]. 35(3):311-316(2016)DOI:
Determination of Furoic Acid in Transformer Oil by Using Reversed Phase Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography
With water as an extractant,a method was established for the determination of furoic acid in transformer oil by reversed phase liquid-liquid microextraction(RLLME) coupled with high performance liquid chromatography(HPLC).The effects of some important parameters,such as pH value and amount of extractant,amount of the diluent(n-hexane),extraction time and centrifugal rotational speed were investigated.The optimum experimental conditions were as follows:extraction solvent:neutral ultrapure water;amount of extractant:150 μL;ratio of dilution:Voil∶Vn-hexane=3∶1;extraction time:5 min;centrifugal rotational speed:5 500 r/min.The quantitative analysis of furoic acid in the transformer oil sample was performed by HPLC.The calibration curve was linear in the range of 0.05-5.00 mg?L-1 with a correlation coefficient(r)of 0.999 9 and a detection limit of 9.6 μg?L-1.The relative standard deviation(RSD,n=6) was 1.4%and the enrichment factor of furoic acid was 13.6.The recoveries of furoic acid in aging transformer oil sample ranged from 99.7%to 105.1%.The qualitative analysis of furoic acid in aging transformer oil was further carried out by using HPLC-MS.This study has established a simple and effective method for the detection of furoic acid in transformer oil and provided useful data for the research on the aging characteristic parameters of transformer oil-paper insulation.
Determination of Contents of Copper and Iron Ions in Transformer Oil by Inductively Coupled Plasma Mass Spectrometry with Reversed Phase Switchable Hydrophilic Solvent Liquid-Liquid Microextraction
Determination of Tetracyclines in Environmental Water Samples by High Performance Liquid Chromatography with Multi template Molecularly Imprinted Polymer Magnetic Solid Phase Extraction
Determination of Corrosive Sulfide Dibenzyl Disulfide in Transformer Oil by High Performance Liquid Chromatography with Liquid-Liquid Microextraction
Experimental Techniques and MethodsDetermination of a Novel Anti AIDS Drug ACC007 by High Performance Liquid Chromatography with Ultrasound assisted Ionic Liquid Dispersive Liquid-Liquid Microextraction
Effects of Three Kinds of Solid Phase Extraction Columns Purification Methods on Determination of 8 Antibiotics Residues in Dairy by High Performance Liquid Chromatography
Related Author
No data
Related Institution
Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, South-Central Min Zu University
College of Chemistry and Materials Science,South-Central Min Zu University