Simultaneous Determination of 18 Phenols Pollutants in Water Samples by High Performance Liquid Chromatography-Tandem Mass Spectrometry
|更新时间:
|
Simultaneous Determination of 18 Phenols Pollutants in Water Samples by High Performance Liquid Chromatography-Tandem Mass Spectrometry
Vol. 35, Issue 8, Pages: 974-980(2016)
作者机构:
四川省环境监测总站
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Simultaneous Determination of 18 Phenols Pollutants in Water Samples by High Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(8):974-980(2016)
DOI:
Simultaneous Determination of 18 Phenols Pollutants in Water Samples by High Performance Liquid Chromatography-Tandem Mass Spectrometry. [J]. 35(8):974-980(2016)DOI:
Simultaneous Determination of 18 Phenols Pollutants in Water Samples by High Performance Liquid Chromatography-Tandem Mass Spectrometry
A method was developed for the simultaneous determination of 18 phenols pollutants in water samples by high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS) combined with direct injection.The water samples were filtered through 0.22 μm of polytetrafluoroethylene(PTFE) microfiltration membrane.With methanol-0.01 mol/L ammonium formate/ formic acid aqueous solution (pH 4.0) as mobile phase,the separation was performed on a Thermo Hypersil ODS column(100 mm×2.1 mm,5.0 μm) by gradient elution.The flow rate was 0.2 mL/min.The column temperature was 30 ℃.Samples were detected in multiple reaction monitoring (MRM) mode with negative electric spray ionization.The phenols pollutants were quantified by the external standard method.The calibration curves of the phenols pollutants showed good linearities in a certin concentration range with correlation coefficients(r2) not less than 0.999 1,the detection limits of phenols pollutants ranged from 0.02 μg/L to 0.51 μg/L.The relative standard deviations(RSD,n=6) of 18 phenols pollutants were in the range of 0.6%-4.3%.The spiked recoveries of 18 phenols pollutants at low,medium and high levels ranged from 84.5% to 112%.The method was sensitive,rapid and little interference.It is suitable for the simultaneous determination of 18 phenols pollutants in relatively clean water samples,such as groundwater and surface water.
关键词
高效液相色谱-串联质谱法酚类污染物地表水地下水直接进样
Keywords
high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)phenols pollutantssurface watergroundwaterdirect injection
Trace Determination of Carbofuran, Aldicarb and Its Metabolites in Groundwater by LC-MS/MS with Direct Injection
Determination of Trace Aniline and Benzidine in Environmental Water by Ultrahigh-pressure Liquid Chromatography with Fluorescence Detection
Simultaneous Determination of Benzotriazoles and Benzothiazoles in Surface Water by Solid Phase Extraction and High Performance Liquid Chromatography-Tandem Mass Spectrometry
Determination of Sulfonylurea Herbicides in Environmental Water Using Solid Phase Extraction Disk Followed by High Performance Liquid Chromatography
Determination of 42 Semivolatile Organic Compounds in Groundwater by Gas Chromatography-Mass Spectrometry