Determination of Four Monoamine Neurotransmitters in the Mouse Brains by Ultra Performance Liquid Chromatography with High Resolution Quadrupole Time of Flight Mass Spectrometry
|更新时间:
|
Determination of Four Monoamine Neurotransmitters in the Mouse Brains by Ultra Performance Liquid Chromatography with High Resolution Quadrupole Time of Flight Mass Spectrometry
Vol. 35, Issue 12, Pages: 1569-1574(2016)
作者机构:
1. 广州质量监督检测研究院国家加工食品质量监督检验中心
2. 广东药学院广东省代谢病中西医结合研究中心
3. 广东出入境检验检疫局检验检疫技术中心
4. .广东工业大学轻工化工学院
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
Determination of Four Monoamine Neurotransmitters in the Mouse Brains by Ultra Performance Liquid Chromatography with High Resolution Quadrupole Time of Flight Mass Spectrometry. [J]. 35(12):1569-1574(2016)
DOI:
Determination of Four Monoamine Neurotransmitters in the Mouse Brains by Ultra Performance Liquid Chromatography with High Resolution Quadrupole Time of Flight Mass Spectrometry. [J]. 35(12):1569-1574(2016)DOI:
Determination of Four Monoamine Neurotransmitters in the Mouse Brains by Ultra Performance Liquid Chromatography with High Resolution Quadrupole Time of Flight Mass Spectrometry
An ultra performance liquid chromatography-high resolution quadrupole time of flight mass spectrometric(UPLC-Q-TOF-MS) method was developed for the determination of four monoamine neurotransmitters including dopamine(DA),serotonin hydrochloride(5-HT),3,4-dihydroxyphenylacetic acid(DOPAC) and homovanillic acid(HVA) in mouse brains.Samples were homogenized with 30% ethanol solution(formic acid pH 5.0),freezingly centrifuged and filtered.Under the optimized chromatographic and mass spectrometric conditions,data were acquisited with electrospray ionization(ESI) and atmospheric pressure chemical ionization(APCI) composite sources in positive ion/negative ion mode.The calibration curves of four monoamine neurotransmitters showed good linearities(r>0.999 3) within the concentration range of 0.5-1 000 μg/L.The limits of detection were in the range of 0.5-5.0 μg/L,and the average recoveries were 93.3%-101.8% with relative standard deviations(RSDs) of 1.1%-3.3%.This method showed the advantages of simplicity,efficiency,high recovery,good sensitivity and high precision,and was suitable for the determination of four monoamine neurotransmitters in brain tissue of mouse.
关键词
超高效液相色谱-高分辨飞行时间质谱法(UPLC-Q-TOF-MS)单胺类神经递质小鼠脑组织
Keywords
ultra performance liquid chromatography-high resolution quadrupole time of flight mass spectrometry(UPLC-Q-TOF-MS)monoamine neurotransmittersmousebrain tissue